Introduction: The HX-4 beating homogenizer, also known as a sterile homogenizer, can directly extract bacteria from solid samples. Simply add the original sample (larger ones need to be cut into approximately 10 x 10mm blocks) and diluent into a sterile sample bag, and then place the sample bag into a percussion homogenizer. The pressure is generated by the blade's impact, causing oscillation, accelerating mixing, and achieving a uniform distribution of microbial components in the solution to complete the sample processing. Effectively separate microbial homogeneous samples contained within and on the surface of solid samples, ensuring that all samples are mixed in sterile bags. After homogenization, the sample can be used as a representative for subsequent analysis without the risk of sample changes or cross contamination. The use of disposable sterile homogeneous filter bags for isolation operation ensures hygiene and safety, does not come into contact with instruments, has no sample leakage and does not require systematic cleaning. It has the characteristics of convenience, speed, accurate results, soft homogenization, small sample contamination, no damage, no temperature rise, no need for sterilization treatment, no need to wash utensils, and good repeatability. Features: 1. It adopts a large LCD display, which is convenient to operate and can store 8 sets of work programs; 2. Intelligent control, with controllable homogenization speed and time; 3. Glass transparent windows are easy to observe, fully open doors are easy to clean; 4. There is no contact between the sample and the homogenizer. If there is no sample leakage, there is no need for system cleaning; 5. Homogenized and soft, the sample is pollution-free, undamaged, does not heat up, does not require sterilization treatment, and does not require washing of utensils; 6. Has strong sound insulation ability. Technical parameters: Model: HX-4 Control method+parameter storage: microcomputer control+8-segment combination programming Temperature control range ℃: None Disinfection function: None Gross weight kg: 24 Display method: 4.3-inch capacitive screen Clapping time: 0.1-99:59:59 seconds or continuous operation Clash speed (times/second): 3-12 Effective volume ml: 3-4 00 Sterile bag size cm: 17x30 Clamping box: stainless steel+anti-corrosion spray coating Tap spacing: 0-50mm adjustable Start mode: Soft start Pause function: Yes Power supply/power: 220V/200W Anti pinch function: equipped with automatic stop anti pinch function Other: detachable windows+tempered glass safety doors External dimensions mm: 460 * 250 * 330
Introduction: The HX-4 beating homogenizer, also known as a sterile homogenizer, can directly extract bacteria from solid samples. Simply add the original sample (larger ones need to be cut into approximately 10 x 10mm blocks) and diluent into a sterile sample bag, and then place the sample bag into a percussion homogenizer. The pressure is generated by the blade's impact, causing oscillation, accelerating mixing, and achieving a uniform distribution of microbial components in the solution to complete the sample processing. Effectively separate microbial homogeneous samples contained within and on the surface of solid samples, ensuring that all samples are mixed in sterile bags. After homogenization, the sample can be used as a representative for subsequent analysis without the risk of sample changes or cross contamination. The use of disposable sterile homogeneous filter bags for isolation operation ensures hygiene and safety, does not come into contact with instruments, has no sample leakage and does not require systematic cleaning. It has the characteristics of convenience, speed, accurate results, soft homogenization, small sample contamination, no damage, no temperature rise, no need for sterilization treatment, no need to wash utensils, and good repeatability.