Brief introduction: This system can be completed in mice and rats (or guinea pig) single or multiple substance in liquid aerosols, gas and dust aerosol and nanoparticles, aerosol, smoke aerosol state acute, subacute, and chronic, chronic systemic inhalation exposure experiments on animals, has been the Chinese center for disease control and prevention, nanjing center for disease control, military academy of medical sciences, university of science and technology, liaoning guangxi medical college, Beijing cigarette factories and other units to use. Features: 1. The unique structural design and precision control system to ensure the samples in the gaseous state or aerosols (liquid aerosols, dust aerosols, etc.) in the canister Lumen concentration distribution, the gas concentration error is less than + / - 5%, error is less than + / - 8%, liquid aerosols and dust aerosol dust and aerosols 2. With prediction with the dose, dose prediction system is convenient to prepare the sample amount. 3. A variety of specifications of the sample, transmission device, meet the needs of different customers different samples. 4. Implementation of mass concentration of the test accord with the related provisions on OECD403 and OECD436 dynamic monitoring. 5. Realize real-time online detection aerosol particle size distribution and particle size analysis by hand. 6. Animal behavior real-time monitoring and remote monitoring. 7. Easy disinfection and thoroughly. 8. Waste water, waste gas discharge completely meet the national safety standards. 9. The unique design of safety shielded cabinet and double canister cavity pressure control to ensure the protection, Protective alarm system for abnormal temperature, pressure difference and gas leak anomalies often make protection and alarm. 10. The human-computer interaction interface, intuitive operation, convenient. 11. Compatible with double system control system, can realize the experiment site control and remote computer control. 12. Powerful hardware and software supporting system, can control 16 sets of "animal body dynamic exposure system", software conforms to the requirements of GLP.
This system can be completed in mice and rats (or guinea pig) single or multiple substance in liquid aerosols, gas and dust aerosol and nanoparticles, aerosol, smoke aerosol state acute, subacute, and chronic, chronic systemic inhalation exposure experiments on animals, has been the Chinese center for disease control and prevention, nanjing center for disease control, military academy of medical sciences, university of science and technology, liaoning guangxi medical college, Beijing cigarette factories and other units to use.