Position: Home > > Measurement instrument > Surface measuring instrument > Optical Surface Analyzer > HARKE-SPCAX2 contact Angle tester for Polymer material analysis

HARKE-SPCAX2 contact Angle tester for Polymer material analysis

Product ID:CLBMgxbm012

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberHARKE-SPCAX2
    Brand NameBJHKSYYQC
    Payment TermsT/T, paypal
    Brief introduction:
    Our company is the birthplace of * Taiwan surface tension/contact Angle tester. It is also the drafting unit for the formulation of national standards and indicators *. Participated in the formulation of GB/ t24368-2009 contact Angle measurement method for the detection of hydrophobic pollutants on glass surface. Automatic surface tension/contact Angle  ester is a new product of Z. The product has advanced technology, compact structure, novel appearance and convenient operation. The mobile mechanism all USES the import Japanese parts, the liquid injection instrument movement pure American original installment, the test software for the company independent research and development. Clear interface and accurate test.
    Main technical indicators and parameters:
    Measuring range of contact Angle tester: 0-1800
    Measuring accuracy of contact Angle measuring instrument: ±  0.10
    Test method of contact Angle tester: base drop method, rotary drop method
    Contact Angle analysis methods: tangent method, ring method, ellipse method, local contour analysis method, total contour analysis method, yang-lapulas analysis method, dynamic tracking analysis method, curve ruler method.
    Contact Angle image processing: manual processing/automatic processing in one
    Surface energy measurement method: Zisman Fowkes Owens
    Determination of liquid: adhesion work, spreading coefficient
    Continuous variable magnification precision microscope (variable magnification without zoom)
    Digital CMOS camera
    Video/replay
    Instant screenshot, according to the set interval screenshot
    Video any movie sheet exported
    Table size: 100mm× 120 mm
    Table movement: up and down 0-50mm automatic about 0-50mm before and after 0-30mm
    Table scale up and down: 30mm
    Table fixed plate movement: 150mm before and after
    Sampler movement: automatic up and down 0-30mm left and right 0-80mm
    Microscope movement: front and rear 80mm
    Continuous automatic injection system: injection range 250μ
    L, injection precision: ± 0.1 & mu;
    Manual injection assembly: injection range: 2ml, injection precision: ±0.1 & mu;
    Electric heating table system:
    Sample size: 100mm (width) 80mm (thickness) ×
    Instrument dimensions: 230mm (width) ×
    640mm (length) ×750 mm (high)
    Application:
    Spray, paint, paint and ink formulation design and wettability analysis
    Test surface adhesion of printing, coating, electroplating and painting
    Analysis of surface adsorption/absorption processes of films, fabrics, paper, etc
    Glass, LCD, touch screen and other surface treatment effect and cleanliness detection
    Wafer, PCB board, LED, high precision components and other organic pollution detection
    Analysis of wettability behavior of hydrophilic aluminum foil, core, mineral, asphalt, insulator, etc
    Analysis of wettability and adsorption of polarizer, film and lens
    Surface competition, adsorption and permeability analysis of pharmaceutical, food and polymer
    Analysis and application of surfactants such as cosmetics, emulsions, petroleum, etc
    Surface tension analysis of detergents such as soap and detergent
    Characterization analysis of fiber, carbon fiber, glass fiber and resin
    Determination and study of wettability between nanomaterials and different active agents
    Study and test the adhesion degree between adhesive and solid
    Cleaning industry cleaning effect detection


     
  • Brief introduction:
    Our company is the birthplace of * Taiwan surface tension/contact Angle tester. It is also the drafting unit for the formulation of national standards and indicators *. Participated in the formulation of GB/ t24368-2009 contact Angle measurement method for the detection of hydrophobic pollutants on glass surface. Automatic surface tension/contact Angle  ester is a new product of Z. The product has advanced technology, compact structure, novel appearance and convenient operation. The mobile mechanism all USES the import Japanese parts, the liquid injection instrument movement pure American original installment, the test software for the company independent research and development. Clear interface and accurate test. 
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com