Performance features: Featuring 12.1-inch super large screen, new color LCD display (TFT-LCD), latest industrial design appearance and portable design. The new large font display design makes it possible for medical personnel to observe clearly from all directions and from a long distance. The Taiwan precision machinist makes blood pressure, blood oxygen and ecg circuit boards. Each module module module module is controlled by an independent CPU. Equipped with unique anti-defibrillation and anti-interference performance of high frequency electrotome, it is suitable for use in surgery, plastic surgery and cosmetic surgery department and gynecological operating room. The unique anti-weak perfusion performance makes it suitable for use in wards and operating rooms. The long-life blood pressure charging pump (colin, Japan) is designed for long and frequent use in hospitals. The simultaneous display of ecg seven waveforms and patients' physiological information values makes it easier for doctors to diagnose and analyze, and satisfies the clinical needs of hospitals at all levels. Ending 384 hours of trend data memory and dynamic waveform capture The upper and lower limits of alarm can be set at will, and the automatic acoustooptic dual alarm can be made This product is widely used in internal medicine, surgery, operating room, gynecology and obstetrics, pediatrics, emergency center, ICU and CCU Technical parameters: Monitor 7 vital signs: 1. Ecg 2. Heart rate 3. Blood pressure 4. Body temperature 5. Oxygen saturation 6. Pulse 7. Breathing ECG ECG Lead: lead all, Ⅰ, Ⅱ, Ⅲ, aVF, aVR, aVL, V1-6 lead thoracic display Gain selection: * 1, * 2, * 4, and * 0.5 Frequency: diagnostic mode: 0.05 ~ 130Hz Monitoring mode: 0.5 ~ 40Hz Operation mode 1 ~ 20Hz Scanning speed: 12.5mm/S, 25mm/S and 50mm/S. Heart rate range: adult 15-300bpm (stroke/min) BPM (stroke/score) Heart rate accuracy: + / - 1% or + / - 1bpm, large Calibration signal: 1mV (peak value, accuracy plus or minus 5%) ST segment detection: measurement range (-2.0mV ~ +2.0mV) RESP breathing Respiratory measurement range: 7 ~ 120BrPM (second/point) for adults 7 ~ 150 BrPM(second/point) for children and newborns NIBP blood pressure Technology: oscillography (pulse wave oscillation) Working mode: manual/automatic Measurement unit: mmHg/Kpa Overpressure protection: double safety protection Adult mode 300 mmHg Child mode 240 mmHg Neonatal mode 150 mmHg Blood pressure accuracy: maximum mean error plus or minus 5mmHg; Maximum standard deviation 8mmHg Alarm mode: acoustooptic alarm Alarm preset range and error :(alarm over preset value) The maximum systolic pressure is 40 ~ 250mmHg. The lower limit is 10 to 220mmHg Maximum diastolic pressure 20 ~ 250mmHg; The lower limit is 10 to 220mmHg Blood oxygen saturation of SPO2 Range: 70 ~ 100% : plus or minus 2 DIGIT Measurement error of blood oxygen saturation: 70 ~ 100% : plus or minus 2 Resolution: 1% The pulse Times: 20-300 times/min Alarm mode: acoustooptic alarm Alarm preset range and error: alarm over preset value Upper limit 20% ~ 100%; The lower limit is 10% ~ 99%. TEMP temperature Technology: high sensitive thermistor probe Temperature measurement range: 0 ℃ ~ 45 ℃ Resolution: 0.1 ℃ Temperature accuracy: + / - 0.1 ° C (do not include the sensor error)
Performance features: Featuring 12.1-inch super large screen, new color LCD display (TFT-LCD), latest industrial design appearance and portable design. The new large font display design makes it possible for medical personnel to observe clearly from all directions and from a long distance. The Taiwan precision machinist makes blood pressure, blood oxygen and ecg circuit boards. Each module module module module is controlled by an independent CPU. Equipped with unique anti-defibrillation and anti-interference performance of high frequency electrotome, it is suitable for use in surgery, plastic surgery and cosmetic surgery department and gynecological operating room. The unique anti-weak perfusion performance makes it suitable for use in wards and operating rooms. The long-life blood pressure charging pump (colin, Japan) is designed for long and frequent use in hospitals. The simultaneous display of ecg seven waveforms and patients' physiological information values makes it easier for doctors to diagnose and analyze, and satisfies the clinical needs of hospitals at all levels. Ending 384 hours of trend data memory and dynamic waveform capture The upper and lower limits of alarm can be set at will, and the automatic acoustooptic dual alarm can be made This product is widely used in internal medicine, surgery, operating room, gynecology and obstetrics, pediatrics, emergency center, ICU and CCU