GAS-800 Microwave Gas Injection Pressure Synthesis Reaction System for Organic Chemistry Research

Product ID:SYHCwbhc002

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberGAS-800
    Brand NameYIMA
    Payment TermsT/T, paypal
    Introduction:
    The GAS-800 microwave gas injection pressure synthesis reaction system provides a fast, safe and automated solution for the sample and allows gas to be introduced into the closed reactor in advance and to control the pressure of the injected gas to be accelerated under microwave heating and pressurization conditions Sample reaction and the speed of crystallization of materials for nano-materials, inorganic materials synthesis and high temperature pressure system synthesis, widely used in research institutes, institutions of higher learning and other units.
    Features:
     The instrument uses the temperature and pressure double control system to control the hydrothermal synthesis kettle pressure and temperature and real-time display, and the reactor can be pre-pressurized pressurized, so that the gas involved in the chemical reaction becomes more controllable and safe. And according to the need to select the turntable or magnetic stirring function, making the reaction more fully and evenly. The instrument adopts continuous microwave heating, which greatly prolongs the service life of the instrument and the uniformity of the electromagnetic wave. The cavity is made of 32 liter large volume austenitic stainless steel material, and the door and cavity are closely packed, and the microwave leakage conforms to the national standard. When the pressure inside the tank exceeds the set protection value, the microwave will automatically stop heating. Safety explosion-proof membrane with double insurance function, when the pressure inside the tank can withstand the pressure of the explosion-proof membrane, the explosion-proof membrane first rupture, gas leakage, to prevent damage to the tank and the human body damage.
    Technical Parameters:
    1. Microwave power 0 ~ 1000W automatically adjustable;
    2. Temperature rise, temperature control range: 0 ~ 260 , temperature measurement accuracy: ± 0.1 ; Temperature control accuracy: ± 1
    Pressure control range: 0 ~ 6MPa, the maximum pressure 10MPa, pressure measurement accuracy: 0.01MPa, detection frequency: 150 ~ 200 data / sec;
    4. Pressure monitoring system: real-time detection of reaction system pressure changes (0 ~ 100Bar), to set the pressure in time to warn and automatically turn off the microwave power;
    5. Large-capacity stainless steel cavity, the surface of multi-layer Teflon treatment, corrosion resistance, high temperature;
    6. Volume of 100ml hydrothermal reactor, outside the tank using imported PEEK material, the tank for the PTFE material;
    7. Select more sample processing, select 1 or 6 samples at the same time;
    8. Provide different speeds of magnetic stirring, so that the reaction more fully, the temperature is more uniform; (optional)
    9. Touch control panel, large-screen LCD display, real-time display of closed reaction tank temperature, pressure, and real-time display temperature and pressure curve can be set step by step temperature and pressure values ​​and can store 16 reaction data set, each data set 10 reaction stages;
    10. Automatic protection function: When the temperature control and control of a system failure, the instrument will automatically cut off the microwave launch, and alarm;
    11. remote control device, in a state of emergency to stop the reaction;
    12. Cooling function: After the reaction is completed, the microwave stops firing, the fan continues to work for 15 minutes, until the tank is cooled, the instrument automatically shuts down;
    13. The furnace chamber is equipped with a high-power exhaust system, and various reactions can be carried out continuously for a long time in a ventilated, safe and easy-to-observe environment. Furnace ventilation using acid corrosion, large air volume centrifugal fan, exhaust volume of not less than 5M ³ / min;
    14. Microwave leakage in line with national standards;

  • GAS-800 Microwave Gas Injection Pressure Synthesis Reaction System
    Introduction:
    The GAS-800 microwave gas injection pressure synthesis reaction system provides a fast, safe and automated solution for the sample and allows gas to be introduced into the closed reactor in advance and to control the pressure of the injected gas to be accelerated under microwave heating and pressurization conditions Sample reaction and the speed of crystallization of materials for nano-materials, inorganic materials synthesis and high temperature pressure system synthesis, widely used in research institutes, institutions of higher learning and other units.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com