1 Sales G3CV multi-parameter animal monitoring,Manufacturer
Position: Home > > Life science instrument and equipment > Animal experimental apparatus > Animal monitor > G3CV multi-parameter animal monitoring

G3CV multi-parameter animal monitoring

Product ID:SHDWjh017

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberG3CV
    Brand NameSHXQ
    Payment TermsT/T, paypal
    Main features:
    1. Strong anti-interference ability of high-frequency electrotome, no matter "cut" or "coagulate", the electrocardiogram waveform and heart rate are not affected;
    Rapid recovery of defibrillation resistance;
    Especially suitable for emergency room and operating room.
    2. Unique impedance and nasal tube respiratory detection function.
    (when a patient is unable to fully lie still, the correct breathing pattern and respiration rate can only be obtained by the nasal tube respiratory test.)
    3, 10.4 "color, high brightness, wide Angle liquid crystal display (TFT), can display 7 waveforms on the same screen, with unique volume and brightness adjustment.
    4. Streamlined design with a sense of time;
    Folding handle, easy to carry.
    5. International operation interface, with a variety of languages: Chinese, English, Spanish, Portuguese, French, Russian and Arabic, etc.
    6. Popup menu plus rotary shuttle operation, friendly man-machine dialogue interface, easy and convenient operation.
    7. Low power consumption design and standby function;
    Built-in high energy charging battery.
    8. Rapid and accurate blood pressure measurement, with the function of venous puncture.
    9. Advanced digital blood oxygen technology can detect hypoperfusion weak pulse blood oxygen.
    10. It has the functions of drug concentration calculation, pacing analysis, ST segment analysis, and arrhythmia analysis.
    11. It can display dynamic respiratory oxygenation diagram, 7 conduction ecg and big-character mode on the same screen;
    Can store 5 custom screen modes.
    12. Comprehensive alarm with sound and light, the upper and lower limits of each alarm parameter can be adjusted.
    13. It can be applied to the guardianship of adults, children and newborns.
    14. It can be applied to the bedside monitoring and the monitoring during the transfer;
    It is widely used in ward, emergency room, operating room, postoperative resuscitation room, ICU, CCU, etc.
    15. Independent wide area network communication function, supporting remote monitoring, diagnosis and software upgrade;
    Support wired wireless mode and central monitoring system networking.
    16. Optional printing function, printing waveform, trend table and trend chart.
    17. Optional carbon dioxide detection function.
    Main technical indicators:
    Stallion (ECG)
    Heart rate (HR)
    Measurement range: 30BPM ~ 350BPM;
    Measurement accuracy: 1BPM or plus or minus 1%, whichever is greater.
    Heart rate alarm Settings and tolerances:
    Upper limit (60 ~ 300) BPM, tolerance plus or minus 10%
    Lower limit (10 ~ 200) BPM, tolerance plus or minus 10%
    Ecg noise level: less than 30 degrees Celsius
    Ecg frequency response: filtering mode: (1 ~ 25) Hz
    Non-filtering method :(0.05 ~ 100) Hz
    The current of the ecg input circuit is less than 0.1
    Ecg display sensitivity: continuous adjustable
    Scan speed segmentation and error:
    The scanning rate can be selected in 3 files: 12.5mm/s, 25mm/s and 50mm/s
    Scanning speed error: less than or equal to 10%
    Throughout noninvasive blood pressure (NIBP)
    Measuring range
    A) systolic pressure (SBP) :(5.3 ~ 36.0) kPa, or (40 ~ 270) mmHg
    B) diastolic pressure (DBP) :(2.7 ~ 26.7) kPa, or (20 ~ 200) mmHg
    C) average pressure (MAP) :(4.0 ~ 29.3) kPa, or (30 ~ 220) mmHg
    Measurement accuracy: 0.4kpa (3 mmHg) or + / -2%, both of which are taken as large values.
    Throughout invasive blood pressure (IBP)
    Measurement range: -1.3 ~ 40KPa(-10 ~ 300mmHg)
    Channel: 2 channels
    Sensor sensitivity: 5mv/v/mmHg
    Unit display: KPa or mmHg(optional)
    Staleness respiration rate (RR)
    Measurement range: 0 BPM ~ 120 BPM;
    Measurement accuracy: BPM at plus or minus 1 or BPM at plus or minus 5%.
    One of the things that is involved in this aspect is called balance body temperature (TEMP)
    Temperature channel
    Channel number: 2;
    Body temperature probe configuration: 1 cavity probe, 1 body surface probe.
    Measuring range: 25.0 ℃ to 45.0 ℃
    Accuracy: + / - 0.2 ℃
    Response time: no more than 3 min.
    Stalpulse blood oxygen saturation (SpO2)
    Measurement range :(0 ~ 100) %;
    Measurement accuracy: within the range of plus or minus 2% (70-100) %
    Within the range of + / - 3% (50% ~ 69 %) %
    Aspect ratio (PR)
    Measurement range :(30-250) BPM;
    Measurement accuracy: 1BPM or plus or minus 2%, both of which take a large value.
    Prior to the audit trend review:
    360 hours of historical data can be reviewed
    Grumpy carbon dioxide (CO2) :
    Measurement range: 0 ns ~ 10.0 ns
    Accuracy: plus or minus 2mmHg
    Now, this is a measure of 10 augmentation (> 5 sideline)
    Enter electrocardiogram + respiration + body temperature + noninvasive blood pressure + oxygen saturation (built-in high energy charging battery)
    An alternative configuration: end-of-breath carbon dioxide, thermograph, bidirectional invasive blood pressure, wall and floor mounting brackets
    The overhaul can be used in a central monitoring system, with each workstation connected to a bedside machine: 1 to 16 units, which can be extended to 16 workstations
    The monitor is applicable to environmental conditions
    Working temperature range: (+ 5 ~ + 45 ℃);
    Transportation and storage (- 20 ~ + 55 ℃
    Relative humidity: working less than or equal to 80%
    Transport and storage is less than 93 %
    Atmospheric pressure: working (700 ~ 1060) hPa
    Transportation and storage (500 ~ 1060) hPa
    Adaptive power supply :(100 ~ 240) V a.c. 50/60hz,
    Maximum input power: 80VA
    Fuse: T 1.6a
    Continuous working hours:
    Network power working time: 8 hours or more
    Internal power: > 1 hour (when the battery is full and blood pressure is measured every 10 minutes).
    Signal interface:
    CRT (external monitor) :
    Standard VGA interface (optional)
    PRINTER (external PRINTER)
    PC/AT parallel interface
    NET (external central monitor)
    RJ45 interface
    LINE (external LINE)
    MODEM interface
     
  • Main features:
    1. Strong anti-interference ability of high-frequency electrotome, no matter "cut" or "coagulate", the electrocardiogram waveform and heart rate are not affected;
    Rapid recovery of defibrillation resistance;
    Especially suitable for emergency room and operating room.
    2. Unique impedance and nasal tube respiratory detection function.
    (when a patient is unable to fully lie still, the correct breathing pattern and respiration rate can only be obtained by the nasal tube respiratory test.)
    3, 10.4 "color, high brightness, wide Angle liquid crystal display (TFT), can display 7 waveforms on the same screen, with unique volume and brightness adjustment.
    4. Streamlined design with a sense of time;
    Folding handle, easy to carry.
    5. International operation interface, with a variety of languages: Chinese, English, Spanish, Portuguese, French, Russian and Arabic, etc.
    6. Popup menu plus rotary shuttle operation, friendly man-machine dialogue interface, easy and convenient operation.
    7. Low power consumption design and standby function;
    Built-in high energy charging battery.
    8. Rapid and accurate blood pressure measurement, with the function of venous puncture.
    9. Advanced digital blood oxygen technology can detect hypoperfusion weak pulse blood oxygen.
    10. It has the functions of drug concentration calculation, pacing analysis, ST segment analysis, and arrhythmia analysis.
    11. It can display dynamic respiratory oxygenation diagram, 7 conduction ecg and big-character mode on the same screen;
    Can store 5 custom screen modes.
    12. Comprehensive alarm with sound and light, the upper and lower limits of each alarm parameter can be adjusted.
    13. It can be applied to the guardianship of adults, children and newborns.
    14. It can be applied to the bedside monitoring and the monitoring during the transfer;
    It is widely used in ward, emergency room, operating room, postoperative resuscitation room, ICU, CCU, etc.
    15. Independent wide area network communication function, supporting remote monitoring, diagnosis and software upgrade;
    Support wired wireless mode and central monitoring system networking.
    16. Optional printing function, printing waveform, trend table and trend chart.
    17. Optional carbon dioxide detection function.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com