Technical parameter |
Model | FY-QC6 |
Signal output | RS232 or RS485 | |
Working temperature range | -40℃ - +80℃ | |
Working humidity range | 0…100% | |
Power supply | VDC:12V | |
Data update | 1-120s(adjustable) | |
Power consumption | <3W | |
material | ABS | |
Communication protocol | Modbus protocol | |
Dimension | Ø145 * 195 mm | |
atmospheric temperature |
Working principle:Energy gap temperature measuring element Measure range:-40℃ - +80℃ Accuracy:±0.2 Resolution:0.1℃ Output unit:℃,(real time value) |
|
atmospheric humidity |
Working principle:Polymer capacitor method Measure range:0-100% Accuracy:±2% Resolution:0.1 Output unit:RH(real time value) |
|
atmospheric pressure |
Working principle:capacitance MEMS sensor Measure range:150 - 1020hPa Accuracy:±1 hPa Resolution:0.1hPa Output unit:hPa(real time value) |
|
Wind speed | Working principle:ultrasonic Measure range:0 - 50m/s Accuracy: ±2% Resolution:0.01 Output unit:m/s(real time value) |
|
Wind direction | Working principle:ultrasonic Measure range:0 -359° (no dead corner) Accuracy:<3° Resolution:1° Output unit:°(real time value) |
|
rainfall | Working principle:radar Measure range:0-10mm/min type:rain/snow resolution:0.01mm |