FC-9624 type ( portable type of mining ) automatic water sampler for surface water and wastewater sampling , monitoring of water sources , to carry out investigations and total control of pollution sources dedicated environmental monitoring instruments . It uses common international peristaltic pump water from the MCU control. Users may need to enter the sampling interval , sample volume and sampling methods . It can automatically complete the work online . After mating flow sensor ( with optional ) can be realized sewage metering , flow proportional sampling of double work . This instrument is a portable bottle of water sampling points , built- in lithium battery 12V , suitable for all levels of environmental monitoring stations , automatic water samples after labor and health, scientific research institutes of rivers, lakes, sea or surface water sources , such as determining the sampling point with . Performance indicators 1 Sampling Method:
* Standard sampling:
Sampling delay time : ( 1 ~ 9999 minutes ) can be set at one minute increments
Sampling interval : ( 1 ~ 9999 minutes ) can be set at one minute increments .
Sample volume : 50 ~ 1000ml arbitrary increments 1 ml
Mixed sampling:
Sample dishes delay time : ( 1 ~ 9999 minutes ) set arbitrarily, one minute increments
Sampling interval : ( 1 ~ 9999 minutes ) can be set at one minute increments .
Sample volume : 50 ~ 1000ml arbitrary increments 1 ml
Mixed number of samples : ( 1 to 20 ) Parallel sampling:
Sampling delay time : ( 1 ~ 9999 minutes ) can be set at one minute increments
Sampling interval : ( 1 ~ 9999 minutes ) can be set at one minute increments .
Sample volume : 50 ~ 1000ml arbitrary increments 1 ml
Number of samples in parallel : ( 1 to 24 )
* Flowmeter control sampling:
Optional connection dedicated flowmeter control samples. 1 to 9999 pulses arbitrary increment a pulse. The output pulse should be 5V ~ 15V positive pulse .
* Output pulse flowmeter control samples
1 to 9999 pulses arbitrary increment a pulse. The output pulse should be 5V ~ 15V positive pulse .
2 peristaltic pump flow characteristics :. 3700ml/min, high-speed, high-volume water pumps, pump tube diameter 10m High strength medical silicone tube
3 sample volume error :. ± 8%
4 Sampling Repeatability : ± 5ml.
5 vertical lift :. 8m.
6 levels Suction : 50m, with the sampling tube automatic flushing .
7 water containers : 24 1000ml polyethylene storage bottle .
8 system clock time control error : 1 ≤ 0.1% and 24 ≤ 30S.
9 pipeline system tightness :. ≤-0.05MPa.
10 hours of continuous operation MTBF (MTBF): ≥ 3000h / times. 11 Insulation resistance :> 20MΩ.
12 Large color touch screen 2.8TFT entire Chinese menu , man-machine dialogue , the need for human intervention when both Chinese Hou tips .
13 software lock that protects the instrument setup program will not be modified.
14 10 can be preset and stored procedures used in accordance with the sampling requirements , could later be called directly. 15. Automatically recorded and stored for each sample case . Mating flowmeter , the terms of five- minute intervals can record traffic data for three months , and each data include : month, day , hour, minute ; instantaneous flow ; cumulative traffic flow data in each record of the time interval can be arbitrarily setting , the greater the longer the time interval recording , using cyclic updates. Down the stored data is not lost , so that at any time. Users can use these data and test results of water samples for data analysis .
16 Working temperature : -5 °C to +50 °C.
17 Power :. FC-9624 (AC220V ± 10%), power 60W.
18 Dimensions :. FC-9624 (430X670) mm ( diameter X height) Weight : 23Kg
FC-9624 type ( portable type of mining ) automatic water sampler for surface water and wastewater sampling , monitoring of water sources , to carry out investigations and total control of pollution sources dedicated environmental monitoring instruments . It uses common international peristaltic pump water from the MCU control.