ELSD 9000 Evaporative Light Scattering Detector Introduction
The Omoxidor Evaporative Light Scattering Detector is a universal mass detector that detects any sample that is less volatile than the mobile phase without the need for a chromophore. ELSD sensitivity is higher than that of refractive index detector, it is not sensitive to temperature change, and its baseline is stable. It has been widely used in the detection of traditional Chinese medicine and proprietary Chinese medicines, fatty acids, carbohydrates, amino acids, drugs and polymers, especially for Analytical detection of other UV-absorbable or weakly absorbing chemical components. ELSD Different HPLC's conventional UV detector detection is affected by the functional group or optical properties of the compound. The unique detection principle of ELSD determines its versatility, and the performance of the chromophore-free sample is significantly better than that of the UV detector.
The Omnitor Evaporative Light Scattering Detector has passed CE certification. The mainstream brand liquid chromatography can control the ELSD9000 Evaporative Light Scattering Detector with its liquid chromatography system software to achieve efficient and accurate detection of UV non-absorbent substances. Features
CE safety certification: in line with EU mandatory safety technology requirements to ensure user safety and health
Compact: With a new light path design, compact (26 cm*19 cm*46 cm) for cascading with LC systems
Excellent detection performance: quantitative repeatability reaches RSD6≤1.5%, baseline noise is as low as 0.01 mV, drift is small, and precision is high
Rapid cooling: helps to quickly switch between different detection methods
Nozzle heating: helps to improve the atomization effect, especially when testing oily samples
Linear Gain Adjustment: Gain linear adjustment helps users fine-tune the height of the output peak
Atomization tube adjustment: The atomization angle can be adjusted freely to meet the detection requirements of different samples.
Automatic system detection: 16 instruments daily self-test, multiple safety design, avoiding mobile phase entering the inspection room, reducing instrument maintenance and prolonging service life
Method Management: Method manages up to 10 groups (25 parameters per group), structured menus to simplify user operations
Monitoring alarms: real-time monitoring of temperature, pressure, and flow, and sound and light alarms for abnormal conditions
Control acquisition software: dedicated multi-platform control software, Clarity® dynamic link library, platform support for use with any HPLC chromatography system
Multiple communication modes: RS-232, RS-485, USB, LAN (TCP/HTTP), programmable external event interface
Green energy saving: multiple ways to start standby mode - detector low power state
Audit trail: Chromatography system software meets FDA 21CFR Part 11 requirements with audit trail Technical Parameters
Light source: 650 nm, 30 mW laser
Detector: Photomultiplier
Evaporation temperature range: room temperature ~ 150 ° C (adjustment step 1 ° C)
Atomization temperature range: room temperature ~ 56 ° C (adjustment step 1 ° C)
Temperature control accuracy: ±1 °C
Gas requirements: clean air or nitrogen (2 ~ 5 bar)
Gas flow control: mass flow meter
Gas flow control accuracy: 0.02 L/min
Mobile phase flow range: 0.01 mL/min ~ 3 mL/min
Baseline noise: ≤ 0.01 mV
Baseline drift: ≤ 0.2 mV / 30 min
Minimum detection concentration: 0.5ng
Quantitative repeatability: ≤ 1.5%
Dynamic range: 104 (invariant gain)
Analog output: -1200 mV ~ 1200 mV
Gain: 0.3 ~ 30 continuous adjustment
Output settings: Output auto zero, output offset (-1000 mV ~ 1000 mV)
Sample rate and digital output rate: 100 Hz, 20 Hz
Input and display: 10-key keyboard and 16×2 high brightness screen
Method save: 10 groups of 25 parameters, automatically called
Programmable external events: zeroing, turning off the laser, gas valve and heating
Low power mode: turn off the air source, light source, heating power supply, etc.
Interface: RS-232, RS-485, USB, LAN (TCP/HTTP)
Data Acquisition Software: Chromatography system software meets FDA 21CFR Part 11 requirements with audit trail
Full-featured multi-platform universal ClarityTM chromatography software (used with ColibrickTM)
Power and power consumption: 85 ~ 264VAC, 50Hz
Dimensions (W × H × D): 26 × 19 × 46 cm
Weight: 10 kg
ELSD 9000 Evaporative Light Scattering Detector Introduction
The Omoxidor Evaporative Light Scattering Detector is a universal mass detector that detects any sample that is less volatile than the mobile phase without the need for a chromophore. ELSD sensitivity is higher than that of refractive index detector, it is not sensitive to temperature change, and its baseline is stable. It has been widely used in the detection of traditional Chinese medicine and proprietary Chinese medicines, fatty acids, carbohydrates, amino acids, drugs and polymers, especially for Analytical detection of other UV-absorbable or weakly absorbing chemical components. ELSD Different HPLC's conventional UV detector detection is affected by the functional group or optical properties of the compound. The unique detection principle of ELSD determines its versatility, and the performance of the chromophore-free sample is significantly better than that of the UV detector.
The Omnitor Evaporative Light Scattering Detector has passed CE certification. The mainstream brand liquid chromatography can control the ELSD9000 Evaporative Light Scattering Detector with its liquid chromatography system software to achieve efficient and accurate detection of UV non-absorbent substances.