DZY-022Z X-ray fluorescence sulfur detector Introduction
DZY-022Z X-ray fluorescence sulfur meter uses energy dispersive X-ray fluorescence spectrometry to measure diesel, naphtha, kerosene, residual oil, lubricating base oil, hydraulic oil, jet fuel, crude oil, automotive gasoline and other distillates. Sulfur content in the included hydrocarbons. In addition, the sulfur content of other products, such as: M85 and M100, can also be measured. Features
1. The instrument is a fully automatic instrument. It adopts a special optical path developed by the company to reduce the detection limit to as low as 10ppm.
2. The instrument adopts an advanced color touch screen, which is sensitive to touch and reliable in quality. All the operation and data display of the instrument can be realized on the touch screen. The touch screen layout is user-friendly and the functions are clear at a glance.
3. The instrument uses a multi-channel pulse amplitude analyzer equipped with CPLD, FPGA, DSP and other technologies. This analyzer has very advanced performance and effectively improves the stability of the instrument.
4. The instrument has the ability to quickly detect the sulfur content. The result will be determined in just tens of seconds, and the C / H ratio will be automatically corrected, which is suitable for a variety of samples.
5. The instrument has the ability to shield the background interference of hydrogenated gasoline and diesel, and the obtained data is almost consistent with the combustion method;
6. The instrument has a variety of calculation methods, which eliminates the measurement error caused by the inconsistency between the fuel oil matrix and the standard matrix.
7. The instrument will automatically select the curve suitable for the sample during the test. There is no need to manually change the curve during the measurement.
8. The instrument has an automatic spectrum stabilization function, which can avoid the energy spectrum drift caused by the temperature change and internal attenuation of the detector, so that the instrument can be further guaranteed in stability and accuracy. The instrument only needs to be calibrated once or twice a year.
9. The instrument has an automatic calibration function, which can effectively avoid problems with the stability of the instrument.
10. The experimental curve error of the instrument can be calibrated by one-click operation.
11. The instrument has a powerful storage function, which can store 1000 measurement results for easy inquiry at any time.
12. The detection device of the instrument is placed inside the instrument to reduce the probability of physical damage and prolong the service life of the instrument.
13. The instrument has good radiation protection ability, which can guarantee the safety of laboratory personnel. Technical parameters
1. Measurement range: S analysis range can be adjusted and selected by calibration of the working curve.
2. Measuring range: S% max ~ S% min≤99.9999%; For example: Petroleum sulfur content measuring range: 0.005% ~ 5%.
3. Error and accuracy: meet the requirements of GB / T 17040-2008, GB / T17606-2009, ASTM4294.
4. Measurement time: 30 seconds, 60 seconds, 100 seconds, 150 seconds, 300 seconds. The recommended value is 100 seconds.
5. Lower detection limit: 10ppm
6. Experimental ambient temperature: 5 ℃ ~ 40 ℃
7. Relative humidity: ≤85% (30 ℃),
8. Power supply: 220V ± 20V, 50Hz.
9. Power consumption: <150W.
10. Size: 405mm × 285mm × 165mm
11. Weight: 9.5Kg.
Introduction
DZY-022Z X-ray fluorescence sulfur meter uses energy dispersive X-ray fluorescence spectrometry to measure diesel, naphtha, kerosene, residual oil, lubricating base oil, hydraulic oil, jet fuel, crude oil, automotive gasoline and other distillates. Sulfur content in the included hydrocarbons. In addition, the sulfur content of other products, such as: M85 and M100, can also be measured.