Product use:
Protein gel electrophoresis Product features:
This product is the newest design, is the DYCZ-24DN model mini double vertical swimmer upgrade edition which sells for many years. This product adopts splint structure to locate glue chamber, so as to improve the reliability of leakproof in-situ glue making technology, and multiple heat dissipation design to ensure the best experimental effect.
The in-situ glue making directly installs the glue chamber on the main body of the electric swimming instrument, the glue making and the running glue are in the same position;
Strong compatibility on the electrophoretic body, where two gels of different specifications, one top two, and one extended gel can be used to separate samples that cannot be separated from mini gels, thereby maximizing the resolution of the samples;
Simple design very simple operation requirements and clamping installation design, high-end products simplified;
High strength PC material for injection molding, strong and durable; high transparency in the bottom slot, clear showing no leakage in the electrophoretic state;
Heat dissipation design
1.Sufficient buffer absorption design ensures that there is no overheating in the electrophoresis process ;
2.The positive electrode protection strip of the V - shaped design is matched with the bubble holes on both sides , so that the bubbles attached to the electrode quickly disappear ;
3.The bottom of the tank has a space of 1 cm, which can be stirred with magnetic rod to ensure the equilibrium of buffer temperature and ionic strength;
4.The upper cover has bulging heat dissipation holes, timely discharge of the heat and water mist in the electrophoresis process. Specifications and parameters :
Maximum supply voltage : 200 ( V )
External dimension : ( L × W × H ) : 175 × 163 × 165mm
Gel plate size : 83 × 73 , 83 × 95mm
Specimen grid : 10 , 15 teeth , 1.0 mm thick
10 , 15 teeth , 1.5mm thick
Weight : 1.0kg
Total buffer capacity : 1350ml
Product features:
This product is the newest design, is the DYCZ-24DN model mini double vertical swimmer upgrade edition which sells for many years. This product adopts splint structure to locate glue chamber, so as to improve the reliability of leakproof in-situ glue making technology, and multiple heat dissipation design to ensure the best experimental effect.
The in-situ glue making directly installs the glue chamber on the main body of the electric swimming instrument, the glue making and the running glue are in the same position;
Strong compatibility on the electrophoretic body, where two gels of different specifications, one top two, and one extended gel can be used to separate samples that cannot be separated from mini gels, thereby maximizing the resolution of the samples;
Simple design very simple operation requirements and clamping installation design, high-end products simplified;