    Introduction:
    In recent years, as people pay more and more attention to dietary health, more and more people are paying attention to the indicator of dietary fiber. According to the "Dietary Guidelines for Chinese Residents", it is necessary to consume 25-30g of dietary fiber per day. When choosing products in daily life, attention can also be paid to labels such as "increasing dietary fiber". However, traditional dietary fiber detection experiments have complex operations, long testing time, and low testing efficiency. The automatic dietary fiber analyzer can complete enzymatic hydrolysis, sedimentation, washing and other processes with one click, replacing tedious manual operations with automated operations, effectively improving experimental efficiency. The DF06 dietary fiber analyzer is mainly used for detecting indicators such as total dietary fiber, soluble dietary fiber, and insoluble dietary fiber in food.
    characteristic:
    1. The instrument integrates functions such as automatic liquid addition, heating, stirring, settling, and filtration, replacing manual repetitive operations with instruments, effectively reducing labor costs.
    2. The enzymatic hydrolysis process instrument uses automatic control of the sealing and opening of the reaction bag, which eliminates the need for manual operation and effectively avoids the volatilization of reagents under high temperature conditions.
    3. Adopting a straight through flexible material reaction bag, compared to traditional methods, the sample is automatically transferred to the filtration section after settling, without the need for manual transfer of the sample.
    Accurate and reliable
    4. The instrument is equipped with a fully automatic pipeline cleaning function, which can avoid pipeline blockage caused by enzyme deterioration and improve the accuracy of the instrument's liquid addition.
    5. Due to the direct impact of experimental temperature on enzyme activity, the instrument controls and monitors the temperature of each channel in real-time during the experimental process, improving the temperature control accuracy to within ± 1 and ensuring experimental accuracy.
    6. Non contact stirring method promotes efficient mixing of the sample and enzyme solution, while avoiding direct contact between the stirrer and the sample, effectively avoiding sample loss.
    7. Using a filter membrane instead of a traditional crucible, the filter membrane can be directly digested and ashed with the sample, avoiding errors caused by sample transfer residues in traditional methods.
    Easy and friendly
    8. The ergonomic lifting arm operating platform can adjust the control screen to the appropriate position according to personal habits, making the control process more convenient and friendly.
    9. The instrument is equipped with a method library, which allows users to access preset solutions with one click, automatically completing the experimental process, and improving work efficiency.
    10. Six channels can be independently controlled, and users can choose the number of channels based on the number of samples, making it flexible to use.
    11. The instrument adopts a negative pressure filtration method, which eliminates the need for backflushing and external air sources, making the filtration process more convenient.
    Technical parameters:
    Sample size: 0.2-1g
    Measurement range: 0-100%
    Standard deviation: ≤ 1%
    Temperature control accuracy: ± 1
    Batch processing capacity: 6
    Test time: 3.5 hours at TDF, 1-3 hours for single IDF or SDF (depending on sample type)
    Filtering method: negative pressure filtration, no need for backflushing
    Power supply: AC 220 ± 10 V (50 ± 1) Hz
    Rated power: 1300 W
    Overall dimensions (length × wide × Height: 800 mm ×  350 mm ×  650 mm
    Net weight: 60 kg

  • Introduction:
    In recent years, as people pay more and more attention to dietary health, more and more people are paying attention to the indicator of dietary fiber. According to the "Dietary Guidelines for Chinese Residents", it is necessary to consume 25-30g of dietary fiber per day. When choosing products in daily life, attention can also be paid to labels such as "increasing dietary fiber". However, traditional dietary fiber detection experiments have complex operations, long testing time, and low testing efficiency. The automatic dietary fiber analyzer can complete enzymatic hydrolysis, sedimentation, washing and other processes with one click, replacing tedious manual operations with automated operations, effectively improving experimental efficiency. The DF06 dietary fiber analyzer is mainly used for detecting indicators such as total dietary fiber, soluble dietary fiber, and insoluble dietary fiber in food.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com