CSY-SJC8 Food Formaldehyde Detector Introduction: The CSY-SJC8 food formaldehyde detector adopts the national standard improvement method (GB/T5009.49-2003), which complies with the "Analysis Method for Hygienic Standards of Distilled Liquor and Blended Liquor GB/T5009.28-2003" and can quickly quantitatively detect the content of beer formaldehyde and food formaldehyde. characteristic: 1. Adopting a new instrument structure design, it has a small volume and is easy to carry. No mechanical moving parts, anti-interference and anti vibration, 2. 8-channel design, with two measurement modes for simultaneous activation and single channel activation. When measuring multiple samples, customers can choose their own measurement mode based on their proficiency in operation, in order to minimize measurement errors caused by the coefficient of variation between channels. 3. High accuracy: Imported special LED light source is used, which has good wavelength accuracy and repeatability, comprehensively improving the accuracy of detection results. 4. High degree of automation: Instrument automatic diagnosis system faults, wavelength calibration: automatic calibration 5. Long service life of the instrument: adopting LED light source, automatic switch energy-saving design, and non continuous working mode. The service life can reach 10 years 6. The instrument automatically stores over 8000 measurement data. Built in micro thermal printer, lifetime no need to replace ribbon, real-time printing of detection results, detection report can print vegetable name, inhibition rate, qualification, detection date, and detection unit. It can better reflect the authority of the test results and facilitate public disclosure 7. Equipped with RS-232 interface and USB port, data processing, statistical analysis, and result uploading can be performed through a computer. If our company's food safety monitoring network software is selected, networks at all levels such as province, city, prefecture, and county can be established according to user requirements. Technical parameters: Accuracy error: ± 3% Linear error: ± 5 ‰ Stability: ± 0.001A/hr Wavelength accuracy:<2.0nm Wavelength range: 412nm Transmission density repeatability: ± 1% Data storage: 80000 records Colorimetric dish: 10 × 10mm standard sample cell Appearance size: 350X290X130 (mm)
Introduction: The CSY-SJC8 food formaldehyde detector adopts the national standard improvement method (GB/T5009.49-2003), which complies with the "Analysis Method for Hygienic Standards of Distilled Liquor and Blended Liquor GB/T5009.28-2003" and can quickly quantitatively detect the content of beer formaldehyde and food formaldehyde.