Features: 1. The sterilizer chamber adopts S30408 stainless steel, jacketed boiler pressure vessel use special steel, main manufacturing advanced welding technology and detection means, ensure the sterilizer main body quality, reliable, durable. 2. The sterilization process USES the microcomputer automatic control, high degree of automation, dynamic display of color touch screen can work parameters such as temperature, pressure, time, sterilization phase, more intuitive and convenient operation. 3. The equipment is equipped with many sets of sterilization procedures (fabric, apparatus and instruments, liquid, etc.), also can set working parameters according to user's actual situation. At the same time a vacuum testing, BD test procedure, the vacuum leakage rate is less than 0.13 Kpa/min. 4. Seal door is conform to the regulations of safety interlock (1) the door is not closed lock, sterilization program cannot be started. (2) with the pressure, the locking device to ensure can't turn the handwheel, ensure the safety of the user. 5. Seal design, adopting the mechanical compaction structure has good sealing effect, long service life. 6. The PID temperature control function, by selecting can be fixed heating control parameters automatically, prevent the temperature overshoot. Technical parameters: Product model (manual door) : BXW - 0.6 SDM The sterilization room size (length x width x height) mm: 1200 * 610 * 610 Volume (M3) : 0.6 Apply to power (voltage/frequency) : 380 v / 50 hz Power (KW) : 2.85 Overall dimensions (length x width x height) mm: 1575 * 1240 * 1240 single Steam source: outside
Features: 1. The sterilizer chamber adopts S30408 stainless steel, jacketed boiler pressure vessel use special steel, main manufacturing advanced welding technology and detection means, ensure the sterilizer main body quality, reliable, durable. 2. The sterilization process USES the microcomputer automatic control, high degree of automation, dynamic display of color touch screen can work parameters such as temperature, pressure, time, sterilization phase, more intuitive and convenient operation. 3. The equipment is equipped with many sets of sterilization procedures (fabric, apparatus and instruments, liquid, etc.), also can set working parameters according to user's actual situation. At the same time a vacuum testing, BD test procedure, the vacuum leakage rate is less than 0.13 Kpa/min. 4. Seal door is conform to the regulations of safety interlock (1) the door is not closed lock, sterilization program cannot be started. (2) with the pressure, the locking device to ensure can't turn the handwheel, ensure the safety of the user. 5. Seal design, adopting the mechanical compaction structure has good sealing effect, long service life. 6. The PID temperature control function, by selecting can be fixed heating control parameters automatically, prevent the temperature overshoot.