BT-1600 image particle analysis system Introduction
BT-1600 static image particle analysis system consists of optical microscope, digital CCD camera, image processing and analysis software, computer, printer and other parts. It is the result of combining traditional microscopic measurement methods with modern image processing techniques. Its basic workflow is to capture the image of the microscope through a special digital camera and transfer it to a computer. The particle image is processed and analyzed by special particle image analysis software to obtain the particle size and shape information of each particle. The particle size and shape information of each particle are counted to obtain the particle size (D50) and particle size distribution, average aspect ratio and aspect ratio distribution, average circularity and circularity distribution and other results.
BT-1600 is intuitive, visual, and accurate. It enlarges particles above the micron level by dozens, hundreds, or even thousands of times, and displays the entire particle shape in front of people's eyes. It can not only see the particles, but also measure the size of each particle through a "ruler", and obtain the diameter of all particles through image processing technology, and then obtain the particle size distribution, average aspect ratio, and aspect ratio distribution. BT-1600 adds an intuitive, simple and accurate method for testing the size and shape of powder materials for the research, production and application of powder materials.
BT-1600 still image particle analysis system also has many unique image processing functions, including automatic shooting, automatic segmentation, automatic filling, batch processing of multiple images, accuracy calibration, etc. Many of these "automatic" functions simplify operations and improve efficiency; the batch processing of multiple images function completely overcomes the traditional static image particle analysis system that can only analyze a single image, resulting in too few particles and insufficient representation, resulting Inaccurate issue. It can take many images, process them one by one, and the particles on each processed image are brought together to improve the representativeness. Technical Parameters
Test range: 1-3000μm
Maximum magnification: 160/400/1600/4000 times
Repeatability error: ≤3% (national standard sample D50 deviation)
Accuracy error: ≤3% (national standard sample D50 deviation)
Digital camera CCD: 5 million pixels
Microscope: Domestic biological microscope / imported biological microscope / metallographic microscope
Ruler accuracy: 10μm
Analysis items: particle size distribution, aspect ratio distribution, circularity distribution, monomer particles and particle groups.
Automatic segmentation speed: <1 second
Segmentation success rate:> 93%
Operating system: WinXP / Win7 / Win8 / Win10
Interface method: USB method
Introduction
BT-1600 static image particle analysis system consists of optical microscope, digital CCD camera, image processing and analysis software, computer, printer and other parts. It is the result of combining traditional microscopic measurement methods with modern image processing techniques. Its basic workflow is to capture the image of the microscope through a special digital camera and transfer it to a computer. The particle image is processed and analyzed by special particle image analysis software to obtain the particle size and shape information of each particle. The particle size and shape information of each particle are counted to obtain the particle size (D50) and particle size distribution, average aspect ratio and aspect ratio distribution, average circularity and circularity distribution and other results.
BT-1600 is intuitive, visual, and accurate. It enlarges particles above the micron level by dozens, hundreds, or even thousands of times, and displays the entire particle shape in front of people's eyes. It can not only see the particles, but also measure the size of each particle through a "ruler", and obtain the diameter of all particles through image processing technology, and then obtain the particle size distribution, average aspect ratio, and aspect ratio distribution. BT-1600 adds an intuitive, simple and accurate method for testing the size and shape of powder materials for the research, production and application of powder materials.
BT-1600 still image particle analysis system also has many unique image processing functions, including automatic shooting, automatic segmentation, automatic filling, batch processing of multiple images, accuracy calibration, etc. Many of these "automatic" functions simplify operations and improve efficiency; the batch processing of multiple images function completely overcomes the traditional static image particle analysis system that can only analyze a single image, resulting in too few particles and insufficient representation, resulting Inaccurate issue. It can take many images, process them one by one, and the particles on each processed image are brought together to improve the representativeness.