Introduction: BOKE series chillers are air-cooled chillers and water-cooled chillers, which are widely used in plastic products production, electronic product manufacturing, machining, casting, packaging and printing, purification treatment, ultrasonic cleaning, bio-pharmaceutical, chemical, scientific research, Food production, aquaculture, electroplating, laser processing, powder metallurgy and other fields. BOKE air-cooled chiller has no loss of water, suitable for areas with lack of water resources and poor water quality. Due to forced ventilation, there is no need to worry about icing, it is also very suitable for winter use in the north; BOKE water-cooled chiller needs to be used with cooling tower Suitable for areas with abundant water resources, due to the external cooling tower, it is necessary to clean the cooling towers and pipelines regularly, and to prevent freezing in winter, but the cooling effect is better than the BOKE air-cooled chiller, which is used in the summer with high temperature and high temperature. It is more common, and the low noise is very suitable for production and test environments with noisy requirements. Features: 1. The compressor adopts the imported Copeland fully enclosed scroll compressor imported from the United States, with high energy efficiency ratio, built-in safety protection, low noise, energy saving and durability. 2. Water-cooled condenser adopts seamless toothed external thread copper tube and tube type, CNC lathe fine processing, with excellent heat exchange efficiency, long life, removable and washable; air-cooled condenser with honeycomb fin string efficient The internal thread copper tube is matched with the high efficiency outer rotor fan, and the heat exchange effect is very good. 3. The evaporator adopts Taiwan High-power brand brazed stainless steel plate heat exchanger. The chilled water and refrigerant flow in a narrow and tortuous path formed between the two plates. The refrigerant is easy to evaporate. Achieve complete evaporation to achieve no liquidity, so the refrigeration capacity is larger than that of ordinary shell-and-tube heat exchangers and water tank heat exchangers, but the power consumption is reduced 4. It adopts electronic temperature control digital liquid crystal display controller, Chinese interface, easy to operate and realize automatic control. Precise control of the various temperatures required for industrial processes (5 ° C ~ 35 ° C). Not only the temperature control, but also the man-machine interface function is fully realized and the temperature control accuracy of the unit is guaranteed to be ±0.5 °C. For other temperature ranges, it can be customized as required. 5. Adopt Schneider Electric products from Germany, with perfect electrical protection system, such as lack/phase protection, ultra high/low voltage protection, overheat/overcurrent protection, antifreeze protection, water cutoff protection, etc. 6. The unit adopts humanized design, which has sufficient cooling capacity, small volume, reasonable structure, beautiful appearance and convenient operation. 7. Refill the storage tank on demand or externally to avoid frequent start and stop, automatic or manual replenishment of water. Technical Parameters: Chiller model: BKLS-F130Q Rated cooling capacity: 36kW 31000 kcal/h compressor Form: Fully enclosed scroll Cooling input power kW: 11 Cooling running current A: 21 Condenser Form: Air-cooled finned Condenser area m2: 135 Air volume m3/h: 13500 Evaporator Form: Stainless steel plate heat exchanger Inlet and outlet pipe interface size: DN50 Water volume m3/h: 12 Pump power kW: 1.2 Safety devices: high and low, low pressure, anti-ice, overload, owing phase, reverse phase, water flow protection, etc. Temperature control mode: Electronic temperature automatic control Temperature control range °C: 5-35 Dimensions: length 1700* width 850* height 1500 Voltage: 380V/50HZ
Introduction: BOKE series chillers are air-cooled chillers and water-cooled chillers, which are widely used in plastic products production, electronic product manufacturing, machining, casting, packaging and printing, purification treatment, ultrasonic cleaning, bio-pharmaceutical, chemical, scientific research, Food production, aquaculture, electroplating, laser processing, powder metallurgy and other fields. BOKE air-cooled chiller has no loss of water, suitable for areas with lack of water resources and poor water quality. Due to forced ventilation, there is no need to worry about icing, it is also very suitable for winter use in the north; BOKE water-cooled chiller needs to be used with cooling tower Suitable for areas with abundant water resources, due to the external cooling tower, it is necessary to clean the cooling towers and pipelines regularly, and to prevent freezing in winter, but the cooling effect is better than the BOKE air-cooled chiller, which is used in the summer with high temperature and high temperature. It is more common, and the low noise is very suitable for production and test environments with noisy requirements.