Position: Home > > Analytical instruments > Chromatogram > Adsorption tube aging / activation > BCT700 adsorption tube aging instrument for Sampling tube cleaning

BCT700 adsorption tube aging instrument for Sampling tube cleaning

Product ID:FShuo005

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberBCT700
    Brand NameYIMA
    Payment TermsT/T, paypal
    Introduction:
    BCT700 adsorption tube aging instrument is a supporting equipment developed by Boside Science and Technology Co., Ltd., which is a thermal analyzer (thermal desorption instrument) with independent intellectual property rights. The equipment is mainly used to aging the thermal analysis tube (adsorption tube), the used thermal analysis tube on the BCT700, through the purge of nitrogen heated at high temperature to remove traces of VOC adsorbed above, in order to resolve the tube's next sample be prepared.
    The BCT700 can age up to 21 analysis tubes at the same time. It has 7 groups and 3 groups. When there are few analysis tasks, only one group or two groups can be used. When the analysis volume is large, 21 can be used all at once, which increases the flexibility But also ensure the maximum efficiency, but also to achieve energy and cost savings.
    For the thermal analyzer, you need to do a standard curve to examine the adsorption / desorption efficiency of the desorption instrument, BCT700 standard tube preparation function, greatly simplifying the process, the user can be different concentrations of liquid standard into the 700 injection I, the liquid standard in the gasification chamber is completely gasified, through the inert gas into a clean analytical tube. The temperature of the gasification chamber is independent of the aging temperature of the analytical tube, which greatly facilitates the practical application of the laboratory.
    Features:
    1. Dual zone temperature control: separate aging room and vaporization chamber can achieve a separate temperature control, temperature control accuracy of 0.5 ;
    2. Timing aging: According to the needs of different aging time set, the aging time to end aging automatically, the aging time up to 999min;
    3. Adjustable flow: standard sample preparation flow rate adjustable range 10-100ml / min, aging tube flow through the regulator valve uniform fine tuning (100ml / min);
    4 standard preparation: a special GC inlet and heating design makes the device has a higher vaporization efficiency, sample reproducibility better;
    5. Save carrier gas: independent carrier gas flow path, respectively, control the vaporization chamber and three groups of aging carrier gas flow, and according to the specific needs of the opening and closing of the corresponding flow path;
    6 simple and easy to use: without any professional tools and skills to quickly get started and easy to use, user-friendly operation and simple;
    Specifications:
    Power supply: AC220 50-60Hz 400W
    Aging tube position: 21 (3 × 7)
    Resolution Tube Size: 1/4 inch (can be customized)
    Standard preparation: 1, 1/4 inches (can be customized)
    Heating power: 300W (75W × 4 aging room); 50W (gasification room)
    Dimensions: 380 × 270 × 230mm
    Weight: ≤ 10kg
    Use of the environment: temperature 0-45 , humidity 5-95%
    Temperature range:
    Aging room: room temperature -400 , ± 1
    Evaporation Room: 0-200 , ± 1
    Aging time: 0-999min
    Input pressure: ≤ 0.4MPa
    Aging flow: 0.1MPa, 100ml / min, ± 5ml / min
    Standard standard flow rate: 0.1MPa, 0-100ml / min, ± 1ml / min

  • Introduction:
    BCT700 adsorption tube aging instrument is a supporting equipment developed by Boside Science and Technology Co., Ltd., which is a thermal analyzer (thermal desorption instrument) with independent intellectual property rights. The equipment is mainly used to aging the thermal analysis tube (adsorption tube), the used thermal analysis tube on the BCT700, through the purge of nitrogen heated at high temperature to remove traces of VOC adsorbed above, in order to resolve the tube's next sample be prepared.
    The BCT700 can age up to 21 analysis tubes at the same time. It has 7 groups and 3 groups. When there are few analysis tasks, only one group or two groups can be used. When the analysis volume is large, 21 can be used all at once, which increases the flexibility But also ensure the maximum efficiency, but also to achieve energy and cost savings.
    For the thermal analyzer, you need to do a standard curve to examine the adsorption / desorption efficiency of the desorption instrument, BCT700 standard tube preparation function, greatly simplifying the process, the user can be different concentrations of liquid standard into the 700 injection I, the liquid standard in the gasification chamber is completely gasified, through the inert gas into a clean analytical tube. The temperature of the gasification chamber is independent of the aging temperature of the analytical tube, which greatly facilitates the practical application of the laboratory.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com