- Model Number5E-IRS3600
- Brand NameCSKYYQ
- Payment TermsT/T, paypal
Special functions for fuel control:
1) safety data management: automatic transmission of sample code and weight information, automatic backup and upload of test results.
2) uploaded data includes:
Environmental parameters: environmental temperature and humidity;
Process parameters: instrument running state, time, furnace temperature, etc.
Technical features:
1. Unique dual-oxygen gun, accelerating combustion.
2. Fast analysis response, analyze single sample within 120 seconds on average.
3. 60 samples can be placed at a single time, cyclic lofting, adding, deleting and inserting test samples at any time.
4. Intelligent identification and positioning of samples, automatically complete the test.
5. External balance, sample quality is directly transferred to the computer, without manual input.
6. Intelligent fault diagnosis, crucible position automatic learning.
7. Optional waste gas treatment function can be installed to completely avoid the pollution of laboratory air.
8. The unique air-tight design prevents sulfur dioxide in the air from affecting the experimental results.
9. Real-time monitoring of ambient temperature and humidity in the laboratory.
10. Automatic transmission of sample code and quality information; Test results backup and upload; Experimental data are tamper-proof.
11. Realize login permission management; Information recording of the experimental process.
12. Original voice alarm and fault handling prompt function.
13. Optimize the air path structure, greatly shorten the maintenance time and convenient.
14. Digital flow display function.
60,120, infinity:
The average analysis time of a single sample is 120 seconds, and 60 samples can be placed at a time for cyclic addition. Automatic sample identification, no crucible number, unattended, cyclic testing of automatic infrared sulfur meter.
Technical parameters:
Standard: GB/ t25214-2010 determination of total sulfur in coal by infrared spectrometry
ASTM: D4239-12
Number of samples: 60 samples can be placed at a single time
Measuring range: 0.01% ~ 30% (can be extended to higher level according to user requirements)
Test method: infrared spectral absorption resolution: 0.001%
Sample quality (mg) : coal, coke 100 ~ 400, recommended for 300;
Petroleum products 100 20
Single sample test time (s) : < 120
High temperature furnace temperature (℃) : 1 3 0 0
Precision: in line with GB/ t25214-2010 "determination of total sulfur in coal by infrared spectrometry"
Accuracy: within the uncertainty range of standard samples
Power (kW) : 4
Instrument weight (kg) : 70
Overall dimension (mm) : 1000 x 650 x 700