ZYSP-2 needle flame testing machine / horizontal vertical burning machine Introduction
SPZY-2 horizontal and vertical and needle flame burning machine is based on the provisions of GB-T2408-2008 for horizontal and vertical burning test and GB5169.5-2008 and GB4706.1-2005 for needle flame burning test. The newly developed comprehensive equipment that fully meets the national standards and relevant UL and IEC standards is the only original instrument on the market that neutralizes two different types of test methods. In addition to the originality of the large function of the device itself, the instrument automatically ignites and automatically counts; at the same time, the horizontal and vertical combustion type clamps are controlled by the motor, which can be moved up and down and left and right automatically, without manual hand dialing; the above functions are similar to other manufacturers. The product does not have it.
Design of the horizontal vertical burning test part: GB-T2408-2008 "Test of plastic burning performance - horizontal method and vertical method"
Horizontal vertical burning test part applicable standards: UL94-2006, GB-T 5455, GB-T13488, GB-T5169IEC60695-11-3, IEC60695-11-4, IEC60950-1, IEC695-2
Needle flame test part equipment GB: GB5169.5-2008 Electrical and electronic products fire hazard test Part 5: Test flame Needle flame test method Device, confirmation test GB4706.1-2005 Safety requirements for household and similar electrical appliances Features
Auto-ignition, automatic timing
Simultaneous horizontal and vertical combustion style clamps are controlled by the motor
Can automatically move up, down, left and right, no manual dialing Technical Parameters
1 needle flame part
1. Needle burner: inner hole Φ 0.5mm ± 0.1mm, outer diameter ≤ Φ 0.9mm, length ≥ 35mm,
2. Burner flame angle: 0- 45 ° (arbitrary adjustment)
3. Combustion time: 0-999.9s ± 0.1s can be adjusted arbitrarily (flame automatically advance and retreat, no hands-on operation)
4. Burning time: 0-999.9s ± 0.1s, automatic recording, manual suspension
5. Flame height: 12mm ± 1mm (with height gauge)
6. Needle height: greater than 35mm (inside diameter ф0.5, outer diameter ф0.9)
7. Gas supply: 95% butane gas (can be bottled with liquefied petroleum gas)
8. Adjustable gas volume (flow meter)
9. Temperature test range: 0~1000°C
10. Flame temperature requirement: the time from 100 °C ± 2 °C to 700 °C ± 3 °C within 23.5 seconds ± 1 second
11. Thermocouple: Φ0.5mm imported armored (K type) thermocouple
12. Heat transfer copper block: Ф4.0x6.0mm
13. Test background: black background
14. Test process: automatic control of test procedures, independent ventilation
2 horizontal vertical test section
1. Ambient temperature: room temperature ~ 40 ° C; relative humidity: ≤ 75%;
2. Power supply voltage and power: 220V ± 10% 50HZ power 150W
3. Bunsen burner automatic ignition time: any setting
4. Bunsen burner inner diameter 9.5mm ± 0.5mm
5. Gas source: liquefied petroleum gas (addition industry methane gas during arbitration);
6. Working power supply: 220V AC 50HZ
7. Timing range: 0~999s Timekeeping accuracy: 10s±0.2s 30s±0.2s;
8. Flame time: 0 ~ 999.9S (adjustable)
9. Afterflame time: 0~999.9S (adjustable)
10. Afterburning time: 0~999.9S (adjustable)
11. Burning angle: 0°, 20°, 45°
12. Flame height: 20mm ~ 175mm adjustable
13. Flame temperature: (100-1000) °C adjustable
14. Gas flow rate: gas flow rate adjustable from 105ml/min to 1000ml/min
15. Burning lamp: The inner diameter of the lamp is 9.5±0.3mm, and the length is 100mm±10mm.
16. Time device: can be accurate to 0.5S
17. Position adjustment: The sample holder can be adjusted up and down, left and right, and the combustion seat can be adjusted back and forth.
Introduction
SPZY-2 horizontal and vertical and needle flame burning machine is based on the provisions of GB-T2408-2008 for horizontal and vertical burning test and GB5169.5-2008 and GB4706.1-2005 for needle flame burning test. The newly developed comprehensive equipment that fully meets the national standards and relevant UL and IEC standards is the only original instrument on the market that neutralizes two different types of test methods. In addition to the originality of the large function of the device itself, the instrument automatically ignites and automatically counts; at the same time, the horizontal and vertical combustion type clamps are controlled by the motor, which can be moved up and down and left and right automatically, without manual hand dialing; the above functions are similar to other manufacturers. The product does not have it.
Design of the horizontal vertical burning test part: GB-T2408-2008 "Test of plastic burning performance - horizontal method and vertical method"
Horizontal vertical burning test part applicable standards: UL94-2006, GB-T 5455, GB-T13488, GB-T5169IEC60695-11-3, IEC60695-11-4, IEC60950-1, IEC695-2
Needle flame test part equipment GB: GB5169.5-2008 Electrical and electronic products fire hazard test Part 5: Test flame Needle flame test method Device, confirmation test GB4706.1-2005 Safety requirements for household and similar electrical appliances