1 Sales ZR-1013 Biosafety Cabinet Quality Detector,Manufacturer
Position: Home > > Life science instrument and equipment > Biological engineering equipment > Biological safety cabinet > ZR-1013 Biosafety Cabinet Quality Detector

ZR-1013 Biosafety Cabinet Quality Detector

Product ID:SHGCaqg023

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberZR-1013
    Brand NameQINGDAOZHONGRUI
    Payment TermsTT,PAYPAL
    ZR-1013 Biosafety Cabinet Quality Detector
     
    Introduction:
    ZR-1013 biosafety cabinet quality detector uses potassium iodide method to test the safety protection performance of class II biosafety cabinets, and meets relevant standards such as "JJF 1815-2020 Calibration Specifications for Class II Biosafety Cabinets". It has four working modes: background test, personnel protection, product protection and cross-contamination protection.
    Features:
    1. Equipped with a special aerosol capture sampling head, which can capture aerosols of a specific particle size;
    2. Equipped with a special potassium iodide aerosol generator, calibrated and measured, the generator speed is stable;
    3. Interference cylinder with leveling device (optional);
    4. With bracket, positioning aerosol generator, sampler and simulation arm;
    5. Test data can be exported through U disk or printed by Bluetooth printer;
    6. Equipped with aerosol generator automatic control interface, using PID algorithm, real-time feedback generator speed control;
    7. There are three mode settings of personnel protection test, product protection test and cross-contamination protection test, which can realize one-click start of each mode;
    8. Four-way independent high-life sampler, connected to a high-precision customized mass flowmeter, can directly display the sampler’s suction flow in real time, and the flow is automatically controlled without adjusting the pressure to stabilize the flow.
    Technical parameter:
    Sampling flow: ≥100L/min
    X1, Y1 sampling head Z height position: 1000mm
    Sampling filter: diameter 25mm, pore size 3μm
    Interference cylinder: (6065)mm diameter metal cylinder with simulated arm, length 1100mm
    (the length can be freely combined as needed), simulating the operator's arm operating the safety cabinet,
    with leveling device
    Instrument noise: <65dB(A)
    Working temperature: 0~40
    Power supply: AC (220 ± 22) V, (50 ± 1) Hz
  • Introduction:
    ZR-1013 biosafety cabinet quality detector uses potassium iodide method to test the safety protection performance of class II biosafety cabinets, and meets relevant standards such as "JJF 1815-2020 Calibration Specifications for Class II Biosafety Cabinets". It has four working modes: background test, personnel protection, product protection and cross-contamination protection.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com