ZH-MZ3000 Animal Respiratory Anesthesia Monitoring System Introduction: The solution of the animal respiratory anesthesia monitoring system is to follow the welfare requirements of experimental animals, in order to ensure the stability of the animal physical parameters, timely detect the abnormal animal physical signs, and help the laboratory personnel complete the animal experiment. According to the size of the animal's body weight, provide a certain volume (tidal volume) of oxygen, and respiratory rate to support the normal breathing of the animal, and ensure that the animal is under anesthesia during the operation. It can meet the requirements of animal surgery for respiratory dysfunction caused by long-term or certain diseases (such as cardio-cerebrovascular disease, hypertension, cerebral infarction, thrombosis) and can not breathe independently. It is suitable for mice, rats, guinea pigs, rabbits, cats, dogs, pet pigs and other animals. Closed air/oxygen passage. The evaporator provides a special isoflurane evaporator for animal anesthesia induction or recovery within 2~5min. Technical parameters: Respiratory rate adjustment range: 1 – 200 times/minute Tidal volume adjustment range: 1 – 200ml optional (300ml) Inhalation/exhalation ratio adjustment: 1:5~5:1 (25 respiratory ratios) Automatic pressure relief protection when the suction pressure exceeds 6Kpa. Parameter display: LCD display Control mode: touch button Scope of application: suitable for mice, rats, guinea pigs, rabbits, cats, dogs, pet pigs and other animals Specification of ventilator interface: 6mm diameter pagoda connector, made of stainless steel There are seven specifications of endotracheal tube: 14G, 15G, 16G, 18G, 20G, 22G, 25G Monitoring parameters: ECG, heart rate, blood pressure, blood oxygen, pulse rate, respiration, body temperature With: drug concentration calculation function. Flow control: oxygen 0.0L/min ~ 10L/min The output anesthetic concentration of the evaporator: the concentration can be adjusted in the range of 0~5%, with automatic temperature and flow compensation function, and the evaporator carrier gas flow range is 1~5L/min. Rapid oxygen supply flow: (35~75) L/min. Insufficient oxygen alarm: when the oxygen supply pressure is lower than 0.2MPa~0.05 MPa, there is an audible alarm, lasting for more than 7 seconds, and the sound intensity is greater than 57db. Working voltage: AC 220V/50Hz Working ambient temperature: 0 - 50 ℃ Relative humidity of working environment:<85% Overall dimension: 465 × two hundred and eighty-five × 410mm
Introduction: The solution of the animal respiratory anesthesia monitoring system is to follow the welfare requirements of experimental animals, in order to ensure the stability of the animal physical parameters, timely detect the abnormal animal physical signs, and help the laboratory personnel complete the animal experiment. According to the size of the animal's body weight, provide a certain volume (tidal volume) of oxygen, and respiratory rate to support the normal breathing of the animal, and ensure that the animal is under anesthesia during the operation. It can meet the requirements of animal surgery for respiratory dysfunction caused by long-term or certain diseases (such as cardio-cerebrovascular disease, hypertension, cerebral infarction, thrombosis) and can not breathe independently. It is suitable for mice, rats, guinea pigs, rabbits, cats, dogs, pet pigs and other animals. Closed air/oxygen passage. The evaporator provides a special isoflurane evaporator for animal anesthesia induction or recovery within 2~5min.