Position: Home > > Life science instrument and equipment > Imaging system > Gel imaging system > ZF-258 automatic Gel Imaging and Analysis system

ZF-258 automatic Gel Imaging and Analysis system

Product ID:SHCXnjcx024

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberZF-258
    Brand NameSHJP
    Payment TermsT/T, paypal
    Brief introduction:
    ZF-258 automatic Gel Imaging and Analysis system, using high-tech means of system hardware configuration: high resolution, high quality, high definition CCD camera, automatic computer control, highly programmed, to ensure the recording of DNA/RNA gel, protein gel, The sensitivity of the imprinted hybridization membrane (including Western Southern Northern / dot hybridization film, autoradiography film, enzyme plate, thin layer chromatography plate, chemical fluorescence imaging and so on) was not lost at low illuminance. To control EB pollution to the greatest extent and effectively protect the health of the laboratory operators. It is helpful for researchers to get electrophoretic photos and analysis results safely, correctly and quickly, to get rid of the tedious operation process and to improve working efficiency.
    Scope of application:
    It is widely used in gel electrophoresis. Protein gel. Blotting hybridization autoradiography glue. Enzyme marker. Petri dish Thin layer chromatography and other imaging and image analysis.
    Functional characteristics:
    The automatic control of zoom, focus, aperture, transmission ultraviolet lamp and reflection lamp can be carried out through the chassis panel.
    The automatic control of zoom, focus, aperture, transmission ultraviolet lamp and reflection lamp can be carried out by computer.
    The real-time observation of gel image can be carried out by computer.
    Timing protection function: 10 minutes without any input command, all light sources automatically shut down, extended service life;
    Turn off operation software: the system automatically closes all light sources at the same time;
    The unique design of double-door tapping window on both sides: the user cuts glue directly in the dark box to effectively prevent pollution;
    Drawer type complete seal design: pull off automatically cut off ultraviolet light source, effectively avoid the harm of ultraviolet ray to human body;
    Image features : Adjust image size , brightness , gray scale , contrast , angle , band alignment , reverse color , trim , zoom , and fill .
    Technical indicators and parameters:
    Product name: automatic gel imaging analysis system ZF-258
    Photosensitive chip: American Microvision chip
    Camera: us Microvision High Resolution low Illumination Digital camera
    Detection signal-to-noise ratio: ≥ 56dB
    Effective pixel: 1280g) x 1024v), 1.33 million pixels
    Mirror head: high permeable electric lens F1: 1.2 automatic
    Exposure time: 1 ms-2s
    Detection sensitivity: lower than 20Pg double-stranded DNA stained by EB
    Illumination mode: transmission ultraviolet, transmitted white light, reflected white light (optional transmission blue light)
    Excitation source: transmission: 300 nm, white light (optional blue light 200 x 120mm) Bilateral reflection: reflecting white light lamp (cold light 254nm / 365nm UV reflection 200 x 50mm)
    Filter: standard 590nm, compatible with most fluorescent dyes such as EBN, Sybrary, GoldView, etc.
    Shot area: UV: 200x 250mm white light: 210x 260mm UV: 220x 270mm white light: 210x 260mm
    Tapping observation device: observation window 60 x 125mm, tapping window: 100x 125mm
    Soft parts: imported gel analysis software (Chinese, English version optional).
     
  • Brief introduction:
    ZF-258 automatic Gel Imaging and Analysis system, using high-tech means of system hardware configuration: high resolution, high quality, high definition CCD camera, automatic computer control, highly programmed, to ensure the recording of DNA/RNA gel, protein gel, The sensitivity of the imprinted hybridization membrane (including Western Southern Northern / dot hybridization film, autoradiography film, enzyme plate, thin layer chromatography plate, chemical fluorescence imaging and so on) was not lost at low illuminance. To control EB pollution to the greatest extent and effectively protect the health of the laboratory operators. It is helpful for researchers to get electrophoretic photos and analysis results safely, correctly and quickly, to get rid of the tedious operation process and to improve working efficiency. 
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com