Introduction: The diaper permeability tester is used to measure the absorption rate, rewet performance and penetration performance of diapers and other products. In line with the latest national standards. Features: 1. 5-station design, can carry out independent testing and improve testing efficiency. 2. The test solution used in the test adopts the peristaltic pump to control the dosing method to ensure the stability and repeatability of the dosing, and the dosing accuracy can reach ±1%. 3. The test solution (physiological saline) is heated by a water bath and stored in a glass tank, which will not have any effect on the performance of the test solution. 4. Test sample fixtures for children's diapers: 3 U-shaped bases, 3 sample holders, 3 standard liquid filling modules, and 3 standard pressure modules. 5. Adult diaper sample fixture: 1 U-shaped base, 2 standard liquid filling modules, 2 standard pressure modules. 6. All sample fixtures are precision machined with high-permeability materials, which is convenient for real-time observation of the measurement process, corrosion-resistant and durable. 7. The whole machine adopts the desktop structure design, the operation is stable, and the mobile installation is more convenient. 8. The main control adopts Mitsubishi PLC control, which is accurate and stable. 9. It adopts Kunlun state-of-the-art touch screen for control and display, and menu-based operation in Chinese and English. Technical parameter: 1. Test parameters and dimensions of children's diapers 1.1, U-shaped sample base parameters: B1: L:125±1mm W:122±1mm B2: L:136±1mm W:135±1mm B3: L:154±1mm W:152±1mm 1.2. Standard dosing module parameters: M1: L: 100±1mm W: 80±1mm M2: L:108±1mm W:85±1mm M3: L:125±1mm W:95±1mm 1.3. Standard test pressurization module: Y1: L:100±1mm W:80±1mm Y2: L:108±1mm W:85±1mm Y3: L:125±1mm W:95±1mm 2. Test parameters and dimensions of adult diapers 2.1, U-shaped sample base parameters: L:319±1mm W:200±1mm 2.2. Standard dosing module parameters: M1: L:170±1mm W:70±1mm M2: L:170±1mm W:95±1mm 2.3. Standard test pressurization module: Y1: L:170±1mm W:70±1mm Y2: L:170±1mm W:95±1mm 3. Pressurized pressure: 2.0±0.2 KPa, 4.0±0.2 KPa 4. Liquid flow rate: 480±5ml/min (children), 750±5ml/min (adult) 5. Timing range: 0.00 ~ 9999.99 s 6. Heating range of test solution: room temperature +5℃~50℃ 7. Power supply: AC220V, 300W, 50Hz 8. Dimensions L×W×H: 1470mm×650mm×1000mm
Introduction: The diaper permeability tester is used to measure the absorption rate, rewet performance and penetration performance of diapers and other products. In line with the latest national standards.