    YMZR-3260E Automatic Smoke Dust and Smoke Comprehensive Tester
     
    Introduction
    YMZR-3260E automatic smoke, dust and flue gas comprehensive tester is a portable instrument. It adopts isokinetic sampling and filter membrane (filter cartridge) weighing method to measure smoke and dust mass concentration; it adopts ultraviolet differential absorption spectroscopy technology, non-dispersive infrared technology and electrochemical technology. Measure the mass concentration of toxic and harmful gases such as SO2, NO, NO2, NOx, CO, CO2, H2S, O2; with ZR-D09QT multi-parameter direct reading sampling tube for smoke and dust, it can realize the principle of β-ray absorption and weighing to complete the concentration of exhaust particles. on-site accurate measurement and direct reading. And the measurement of parameters such as flue gas flow rate, flue gas temperature, flue gas humidity, flue pressure, and exhaust air volume. It is suitable for monitoring the emission concentration, total emission, and dedusting and desulfurization efficiency of soot and flue gas in stationary source emissions.
    Features
    1. Built-in UV differential flue gas analysis module and large-flow flue dust sampling pump, which can meet the three standards of HJ 1131-2020, HJ 1132-2020, and HJ 836-2017 at the same time;
    2. Using UV spectral differential absorption technology (DOAS) to measure SO2, NO, NO2 and other gas concentrations in the exhaust gas of fixed pollution sources, with high measurement accuracy, not affected by water vapor in the flue gas, especially suitable for high humidity and low sulfur conditions;
    3. High-precision non-dispersive infrared absorption method measurement module to analyze flue gas components;
    4. Dual-range analysis design, automatically switch the range according to the high and low concentration values ​​of SO2, NO, NO2;
    5. Dynamic display of spectral graphics, which is convenient for users to grasp the working conditions of the instrument;
    6. Imported holographic grating spectrometer is used to perfectly match the absorption spectrum of SO2, NO, NO2 and other components;
    7. The ultraviolet light source adopts pulsed xenon lamp, the preheating time is less than 10min, and the service life is long;
    8. Built-in liquid water protection and automatic drainage device to prevent liquid water in the sampling gas from affecting sampling;
    9. The built-in constant temperature system ensures that the infrared module operates in a constant temperature environment and improves the measurement stability;
    10. Support touch and key operation at the same time, 7.0-inch wide temperature high-brightness multi-angle flip color screen, high temperature resistance, wide field of view, graphical display of Chinese characters, keyboard adopts dustproof and waterproof industrial precision design, suitable for harsh working conditions;
    11. The built-in automatic drainage pump realizes the automatic discharge of condensed water of smoke and flue gas sampling, which can meet the use of high humidity conditions, and the operation is convenient and efficient;
    12. Support bluetooth communication function and external bluetooth high-speed printer;
    13. Equipped with high-load, low-noise and large-flow air pump, the flow rate can reach 110L/min;
    14. The positive and negative pressure-taking nozzles of the pitot tube and the connecting pipeline are color-coded for easy operation;
    15. Equipped with the air tightness of the smoke system and the self-checking and alarm functions of the whole machine, which is convenient for users to use and maintain;
    16. It has the function of air circuit buffer to realize the real anti-suck back and ensure the accuracy of the sampling data;
    17. The integrated design of the host visualized high-quality dust filter element and escape water trap can effectively filter dust and be easy to replace, further remove water, and protect the gas path and sampling pump;
    18. AC and DC voltage power supply, support external power box power supply or AC/DC desktop power adapter power supply, 220V power supply and charging;
    19. With the power-off memory function, during the sampling process, the power is suddenly cut off, the working data is automatically saved, and the incoming call prompts to resume the sampling;
    20. Standard battery 25.9V 6AH, lower power consumption of the instrument, 20L/min, ≥3 hours at -8kPa load, 30L/min, ≥2 hours at -8kPa load; expandable backup power box for power supply;
    21. The flue gas pre-treatment device can effectively dehydrate and remove dust, and enhance the detection accuracy of flue gas components.
    Technical parameter:
    Sampling flow: (0110)L/min
    Working power supply: AC (220±22)V, (50±1)Hz
    Host size: (length 370 × width 170 × height 340) mm
    Host weight: about 12kg (including battery)
    Instrument noise: <65dB(A)
    Power consumption: <600W
  • Introduction
    YMZR-3260E automatic smoke, dust and flue gas comprehensive tester is a portable instrument. It adopts isokinetic sampling and filter membrane (filter cartridge) weighing method to measure smoke and dust mass concentration; it adopts ultraviolet differential absorption spectroscopy technology, non-dispersive infrared technology and electrochemical technology. Measure the mass concentration of toxic and harmful gases such as SO2, NO, NO2, NOx, CO, CO2, H2S, O2; with ZR-D09QT multi-parameter direct reading sampling tube for smoke and dust, it can realize the principle of β-ray absorption and weighing to complete the concentration of exhaust particles. on-site accurate measurement and direct reading. And the measurement of parameters such as flue gas flow rate, flue gas temperature, flue gas humidity, flue pressure, and exhaust air volume. It is suitable for monitoring the emission concentration, total emission, and dedusting and desulfurization efficiency of soot and flue gas in stationary source emissions.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com