YLS-8301-01 Deuterium Halide Lamp Light Source Introduction: YLS-8301-01 deuterium halogen lamp light source is a high stability composite light source composed of deuterium lamp and halogen tungsten lamp, which achieves continuous spectral output of ultraviolet near-infrared. Due to the use of new filtering technology, the characteristic peak spectral lines of the deuterium lamp are suppressed, resulting in a smooth and continuous output spectral curve with high stability, which is very conducive to high-precision quantitative measurement of absorbance, concentration, and transmittance. Easy to replace built-in light bulbs, very convenient for maintenance; The deuterium lamp and halogen tungsten lamp have independent control switches, which can achieve separate output of deuterium lamp spectrum or tungsten lamp spectrum; The power of tungsten lamp can be adjusted, which can achieve the adjustment of tungsten lamp spectral intensity; The electronic shutter controlled by TTL can achieve external trigger control of the light source. Application: It can be used as a reference light source for measuring absorbance, transmittance, and reflectivity; Suitable for scientific research and industrial applications of broadband light sources that require stable output. Features: 1. The entire spectrum is subjected to intensity balance and deburring peak treatment 2. Easy to replace built-in light bulb 3. Dual light source that can be independently turned on/off 4. Tungsten lamp with adjustable power 5. Built in shutter and TTL control Technical parameters: Size: 175mm * 160mm * 265mm Weight: 4.5Kg Wavelength range: 230-2500nm Bulb power: 25W deuterium lamp, 20W tungsten lamp Bulb life: 1000 hours Current stability:<5 × 10-6p-p Current drift rate: 0.01%/h Trigger mode: TTL Input voltage: 100-240V/AC Working temperature: 5 ℃ -35 ℃ Preheating time: 30 minutes
Introduction: YLS-8301-01 deuterium halogen lamp light source is a high stability composite light source composed of deuterium lamp and halogen tungsten lamp, which achieves continuous spectral output of ultraviolet near-infrared. Due to the use of new filtering technology, the characteristic peak spectral lines of the deuterium lamp are suppressed, resulting in a smooth and continuous output spectral curve with high stability, which is very conducive to high-precision quantitative measurement of absorbance, concentration, and transmittance. Easy to replace built-in light bulbs, very convenient for maintenance; The deuterium lamp and halogen tungsten lamp have independent control switches, which can achieve separate output of deuterium lamp spectrum or tungsten lamp spectrum; The power of tungsten lamp can be adjusted, which can achieve the adjustment of tungsten lamp spectral intensity; The electronic shutter controlled by TTL can achieve external trigger control of the light source. Application: It can be used as a reference light source for measuring absorbance, transmittance, and reflectivity; Suitable for scientific research and industrial applications of broadband light sources that require stable output.