YD-335III pathology dual-use slicer Introduction: Pathology dual-use slicer computer fast frozen paraffin dual-use slicer is composed of two parts: YD-335 computer slicer and freezing system. The freezing system of the pathology dual-purpose slicer adopts the principle of high-power semiconductor temperature difference cooling, advanced nano material and liquid crystal display, set temperature, actual temperature, automatic constant temperature control, automatic alarm system, memory function, automatic retraction and automatic removal. Frost function, automatic slice counting function, fast film repair function, improve work efficiency. The pathology dual-purpose slicer handwheel can be locked at any position, and the sample holder can be quickly interchanged. Both frozen sections can be frozen quickly and conventional paraffin sections can be performed. Features: 1. Repair the adjustment index value as small as 1um 2. The cold knife and the back of the knife are sliced at a 45° angle. The smaller the angle, the easier it is. 3. Slice adjustment scale value is as small as 1um 4. The cold knife adopts magnetic adsorption, which is convenient for operation and disassembly. 5. Slice accuracy: ± 5% large capacity waste chute 6. The cold knife cold table displays the preset temperature and real-time temperature respectively on the same screen. 7. With memory, power saving function, automatically retain the set temperature after running; automatic constant temperature 8. The defrosting temperature shows that the dicing temperature can be reached after the defrosting automatically recovers the cooling working state and the cooling speed is 2-7 minutes. Technical Parameters: Slice thickness: 0-100um Slice thickness setting range: 0-10um progressive with 1um, 10-20um with 2um progressive, 20-50um with 5um progressive, 50-100um with 10um progressive. Repair thickness range: 0-500um Freezer table area up to 45×40mm Sample horizontal shift up to 30mm Slice section up to 50×45mm The sample is vertically displaced up to 70mm Freezer temperature difference ≥60 °C Sample automatic feed, automatic retraction: 12um Freezing knife temperature difference ≥ 50 ° C
Introduction: Pathology dual-use slicer computer fast frozen paraffin dual-use slicer is composed of two parts: YD-335 computer slicer and freezing system. The freezing system of the pathology dual-purpose slicer adopts the principle of high-power semiconductor temperature difference cooling, advanced nano material and liquid crystal display, set temperature, actual temperature, automatic constant temperature control, automatic alarm system, memory function, automatic retraction and automatic removal. Frost function, automatic slice counting function, fast film repair function, improve work efficiency. The pathology dual-purpose slicer handwheel can be locked at any position, and the sample holder can be quickly interchanged. Both frozen sections can be frozen quickly and conventional paraffin sections can be performed.