Y09-3016 handheld dust particle counter Introduction
Y09-3016 hand-held dust particle counter is widely used in clean room inspection of electronic production enterprises; on-site detection and leak detection of filters; biosafety monitoring, HVAC system, computer room, beverage packaging environment, pharmaceutical and medical device production environment, hospital Clean operating room, automotive spraying environment, microelectronics, biochemical products, food hygiene, fine chemicals, precision machinery and other production and scientific research departments, HVAC and pharmaceutical companies and their supervision and management departments. Technical parameters
Light source: semiconductor laser, lifetime greater than 35,000 hours
Sampling flow: 2.83L/min (0.1ft3) imported sampling pump
Display mode: LCD display (LCD), real-time display, previous cycle display, real-time density display, display time, date, measured value, temperature and humidity, room number, sampling point, sampling times, battery level, status, etc. 95% UCL calculation, directly showing particle concentration (particles/cubic meter)
Rechargeable battery: Lithium-ion battery, 7.4 V, 2200 mAh.
Power supply: AC adapter, AC: 100V ~ 245 V, 50 / 60 Hz to DC: 7.4 V, 1 A;
Working time: 6 hours (remaining battery indicator)
Counting mode: cumulative value, difference, concentration value
Test method: single, repeat, continuous, calculation, remote,
Unit conversion: Unit can be converted into m3
Particle size channel: 0.3, 0.5, 1.0, 3.0, 5.0, 10μm, six-speed particle size simultaneous counting.
Sampling period: 1~10000(s) Delay count: 0~99(S) Self-cleaning time: ≤10 (min)
Working environment: Temperature: 10~40°C (50~104°F) Relative humidity: 20~90%RH, no condensation. Atmospheric pressure: 86-106KPa
Temperature and Humidity: Optional (1) Temperature: 0~50°C±1°C. (2) Humidity: 0~100%RH±5%
UCL setting: Number of sampling points (A): 2 to 9 points setting. Number of samples per point: (L) 2 to 9 settings Setting position: 0-999
UCL report: in line with ISO14644-1, GB50073-2001, GMP, FS-209E standards
Data storage: It can store 1000 sets of data (circular buffer) (including particle size, data, environmental data, year, month, day, time, sampling amount, data position port), and data is not lost after power off.
Communication interface: RS232, 9600 baud rate
Alarm setting: The instrument has level alarm function, which can be used for clean room 100, 1000, 10000, 100000, 300,000, 1000000 after the alarm. Battery voltage is too low.
Zero count: Meets JJG-547-88 dust particle counter verification procedure requirements JIS B9921:1997 Less than 1 every five minutes
Overlap error: 5%, 2,000,000/cubic feet
Printing function: External printer (optional)
Dimensions: 230 × 130 × 45 (mm)
Weight: 0.6kg
Calibration: It can be traced back to the National Institute of Standards and Technology (NIST). Our company has passed the national measurement and construction assessment, which can be traced back to the Shanghai Institute of Metrology and Measurement Technology. It can also be self-calibrated or calibrated by a third-party national metrology institute.
Standard configuration: suitcase / charger, power sampling head, zero filter, RS 232 cable, computer connection communication software CD
Options: external printer, professional triangle sampling frame, temperature and humidity sensor
Introduction
Y09-3016 hand-held dust particle counter is widely used in clean room inspection of electronic production enterprises; on-site detection and leak detection of filters; biosafety monitoring, HVAC system, computer room, beverage packaging environment, pharmaceutical and medical device production environment, hospital Clean operating room, automotive spraying environment, microelectronics, biochemical products, food hygiene, fine chemicals, precision machinery and other production and scientific research departments, HVAC and pharmaceutical companies and their supervision and management departments.