    XH-800C Temperature and Pressure Dual Control Microwave Digester
    Introduction:
    The XH-800C computer temperature and pressure dual control microwave digestion instrument provides a fast, safe, and automated solution for sample pre-treatment. It is cost-effective and can perform up to 6 microwave digestion experiments simultaneously. It also has 5 safety measures for microwave high-pressure equipment, the same working temperature and pressure, and is committed to providing a safe and reliable user experience and uniform digestion effect.
    Features:
    1. A heating control system with independent intellectual property rights and advanced program heating;
    2. Real time monitoring of the temperature of each jar can automatically stop microwave emission when the temperature exceeds the set and safe range, ensuring the safety of the experiment;
    3. Equipped with strong and fast air cooling, using corrosion-resistant, high-volume centrifugal exhaust fans. After the reaction is completed, the microwave stops emitting, the fan continues to work, and the instrument displays the temperature and pressure values inside the reactor in real time. When the pressure reactor cools down, the instrument beeps to remind the end of the experiment.
    4. The pressure control system adopts high-precision corrosion-resistant piezoelectric crystal pressure sensors;
    5. The microwave resonant cavity is made of austenitic stainless steel and coated with multi-layer Teflon corrosion-resistant coating; Dual magnetrons are arranged vertically with dual ports, and rectangular waveguides are fed coaxially, which can evenly heat the samples in the tank.
    6. Multi layer protective door structure greatly enhances microwave leakage protection and pressure impact protection; The digestion unit digestion turntable can rotate at a coaxial and uniform speed, making the sample more evenly heated in a microwave environment, greatly increasing the precision of the instrument and the consistency of sample digestion and detection accuracy
    During the experiment, the screen can display the temperature, time, power, pressure values, and curves of the reaction system in real-time;
    8. Stop the reaction remotely in an emergency state
    Safety protection system [automatic protection] When a certain system fails during temperature and pressure control, the instrument will automatically cut off microwave emission and give an alarm;
    9. Mechanical and electronic double safety door locks, with automatic cutoff of microwave power supply protection when the chamber door is opened;
    10. In case of accidental overpressure, gas rushes out of the pressure relief hole, causing the airflow to break through the inner cover skirt and leak out, activating dual pressure relief protection;
    11. Multi layered protective door structure, vertical directional blasting, to prevent accidents and protect the safety of personnel and instruments.
    Technical parameters:
    Microwave frequency: 2450MHz, industrial grade microwave source;
    Microwave power: 0~1000W, automatically and continuously adjustable;
    Temperature sensor: Platinum contact temperature sensor;
    Temperature measurement range; 0~260 ;
    Withstand temperature: ≤ 260
    Temperature measurement accuracy: ± 0.1 ;
    Temperature control accuracy: ± 1 ;
    Detection frequency: 150-200 data/second;
    Pressure measurement range: 0-10MPa; Working pressure ≥ 6MPa; Pressure measurement accuracy: 0.01Mpa;
    Circulation: Simultaneously processing up to 6 100ml high-pressure digestion tanks;
    Digestion tank: The outer tank is made of imported PEEK material, and the inner tank is made of polytetrafluoroethylene material; Working temperature ≥ 260 ; Working pressure ≥ 6Mpa (900psi).
    Reaction parameters: Set reaction parameters in sections, totaling 10 sections. Each working section can set microwave power, temperature, and time according to experimental needs, and can store 16 sets of set parameters;

     
     
  • Introduction:
    The XH-800C computer temperature and pressure dual control microwave digestion instrument provides a fast, safe, and automated solution for sample pre-treatment. It is cost-effective and can perform up to 6 microwave digestion experiments simultaneously. It also has 5 safety measures for microwave high-pressure equipment, the same working temperature and pressure, and is committed to providing a safe and reliable user experience and uniform digestion effect.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com