WTF5-B continuous flue gas emission monitoring system
Introduction: The flue gas emission continuous monitoring system (special for formaldehyde detection) is a new type of formaldehyde measuring instrument developed based on years of UV technology experience. This system can solve the problems of electrochemical formaldehyde module poisoning, short maintenance period, and unstable measurement. The minimum range is as low as 50ppm. The formaldehyde meter has been successfully applied to various occasions. It is based on ultraviolet differential absorption spectroscopy for measuring formaldehyde with independent intellectual property rights. Technical continuous flue gas emission monitoring system. Application: Mainly used in lumber mills, paint factories, textile factories and chemical plants where formaldehyde needs to be monitored. Features: 1. Ultraviolet flue gas analyzer has high measurement accuracy, and the detection limit can be as low as 0.5ppm; 2. It is not subject to the cross-interference factors of CO, CO2, CH4 and other substances, and is not interfered by other organic substances; 3. The system has simple structure and high reliability; 4. All core modules and algorithms are independently developed; 5. Compact structure, convenient for transportation and installation. Technical Parameters: CH2O: 0~50ppm, 0~100ppm O2: 0~25% Dust: 0~5mg/m3, 0~50g/m3 Flow rate: 0~40m/s (customizable) Temperature: 0~300℃ (customizable) Pressure: -10kPa~+10kPa (customizable) Size: 800mm×600mm×2000mm Heating temperature: 120℃~180℃ Protection level: cabinet IP42, other IP65 Power supply: 220VAC, 5000W Working temperature: -20℃~+50℃ Working humidity: 0~95%RH (non-condensing) Compressed air requirements: (0.4~0.8) MPa, 0.25m3/min, Clean, oil-free and water-free
Introduction: The flue gas emission continuous monitoring system (special for formaldehyde detection) is a new type of formaldehyde measuring instrument developed based on years of UV technology experience. This system can solve the problems of electrochemical formaldehyde module poisoning, short maintenance period, and unstable measurement. The minimum range is as low as 50ppm. The formaldehyde meter has been successfully applied to various occasions. It is based on ultraviolet differential absorption spectroscopy for measuring formaldehyde with independent intellectual property rights. Technical continuous flue gas emission monitoring system. Application: Mainly used in lumber mills, paint factories, textile factories and chemical plants where formaldehyde needs to be monitored.