Introduction: GB 8368 Single-use infusion set The gravity infusion standard has made clear requirements for the detection method of particulate contamination in the infusion set. This method requires the preparation of eluent and then the detection of the eluent. However, the process of preparing the eluent takes a long time, the operation is cumbersome, laborious, and easy to fail due to improper manual operations. The "WCP-1 particulate pollution test platform" developed by our company can complete the elution, collection and detection of 10 infusion sets at one time, realizing intelligent one-stop operation. The platform is easy to operate and requires no staff to wait during the test process, which greatly saves manpower costs, improves the detection efficiency, and effectively regulates the operation behavior, ensures the consistency of the test process among the infusion sets, and avoids human factors from affecting the authenticity of the test data. Features: 1. Meet the detection requirements of GB 8368-2005 and GB 8368-2018 for particulate contamination of infusion equipment 2. Easy to operate, one-click to complete standard test, no need for personnel to participate, saving manpower 3. With custom standard testing function, it can meet the testing needs of different users 4. Fully enclosed pipeline to prevent external pollution from affecting the test results 5. Strong versatility, can install infusion tubes with different types of joints and trocars 6. Using Windows operating system, strong human-computer interaction ability, can connect multiple peripherals for expansion 7. Mass storage of built-in database, which can be retrieved, analyzed and counted through a variety of conditions 8. Support multi-level account management, permission setting, and provide software report function, which is convenient for internal audit and disposal 9. Supports scanning input, and you can choose a variety of (portable and desktop) methods to print test reports Technical parameter: Inspection quantity: 1-10 Counting channel: 64 channels, thousands of particle sizes can be customized, with an accuracy of 0.1um Particle size range: 10~100µm Injection volume: 2~500ml Injection volume accuracy: ±0.5% (500ml) Counting accuracy: specified value ±10% Standard deviation: <2% (standard particle concentration ≥1000 particles) Limit detection concentration: 10000 grains/ml Power supply: AC220V, 50Hz, 110W
Introduction: GB 8368 Single-use infusion set The gravity infusion standard has made clear requirements for the detection method of particulate contamination in the infusion set. This method requires the preparation of eluent and then the detection of the eluent. However, the process of preparing the eluent takes a long time, the operation is cumbersome, laborious, and easy to fail due to improper manual operations. The "WCP-1 particulate pollution test platform" developed by our company can complete the elution, collection and detection of 10 infusion sets at one time, realizing intelligent one-stop operation. The platform is easy to operate and requires no staff to wait during the test process, which greatly saves manpower costs, improves the detection efficiency, and effectively regulates the operation behavior, ensures the consistency of the test process among the infusion sets, and avoids human factors from affecting the authenticity of the test data.