1 Sales TY-6340 Online Infrared Natural Gas Analyzer,Manufacturer
Position: Home > > Environmental monitoring and analysis > Industrial gas analysis > High purity / gas analysis system > TY-6340 Online Infrared Natural Gas Analyzer

TY-6340 Online Infrared Natural Gas Analyzer

Product ID:HQGYgch020

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberTY-6340
    Brand NameWUHANTIANYU
    Payment TermsTT,PAYPAL
    TY-6340 Online Infrared Natural Gas Analyzer
    Introduction:
    The online infrared natural gas analyzer TY-6340 adopts internationally advanced NDIR non dispersive infrared technology, mainly used to measure the volume concentration and calorific value of gases such as CH4 and CnHm in natural gas. The online infrared natural gas calorific value meter developed by Wuhan Tianyu Intelligent Control adopts a standardized 3U chassis, with high measurement accuracy, simple structure, convenient maintenance, powerful software functions, strong scalability, and good on-site practicality. At present, it is widely used in gas appliance production enterprises and manufacturers, gas measurement and testing departments, energy conservation monitoring departments, scientific research, environmental protection and gas distribution industries, natural gas companies, liquefied gas plants, liquefied gas stations and other fields to measure the volume concentration and calorific value of different components in natural gas.
    characteristic:
    1. Standardized 3U chassis design, aluminum alloy brushed panel chassis with stylish appearance, strong sense of technology, and light instrument weight
    2. Adopting imported NDIR non dispersive infrared sensors and TCD thermal conductivity gas sensors
    3. The instrument measures the volumetric concentrations of six gases, C0, C02, CH4, H2, O2, and CnHm, in the sample gas and outputs the calorific value simultaneously. Increase the enable function of over range limit, ensure measurement accuracy within the range, and enable over range measurement,
    For measurement value reference
    4. Automatic calculation of calorific value, and free switching of calorific value units Kcal/m3 and Mj/m3
    5. The internal gas interference of the instrument is automatically corrected to ensure that there is no interference in the measurement results
    Measure the concentration of CnHm to ensure the accuracy of gas calorific value
    Correcting the interference of CnHm gas on CH4 measurement results and accurately measuring the concentration of CH4
    Correcting the interference of CO, CO2, and CH4 on H2 measurement results and accurately measuring the concentration of Hz
    6. The instrument has the function of intelligent determination of user calibration ventilation concentration, which prevents users from making mistakes and causing the instrument to be unusable
    6. The instrument has a fast response time and can achieve continuous monitoring for 7 * 24 * 365 days
    7. The instrument automatically samples, analyzes, and detects, with fast measurement speed and consumables free use
    8. The equipment is easy to operate and can be used by personnel after on-site training
    9. The equipment is suitable for both continuous monitoring in industrial sites and airbag sampling and analysis in laboratories
    10. Chinese and English software operating systems can be freely switched
    11. The instrument software is powerful and has functions such as automatic data storage, querying, deletion, and USB export. The name of the historical data storage site can be customized (supporting Chinese input), and the measurement data storage time interval can be customized
    12. Equipped with RS485 digital output interface
    13. Product modular design and remote software version upgrade
    Technical parameters:
    Measurement indicators: CH4, CnHm, calorific value display
    Measurement method: CH4, CnHm: NDIR non dispersive infrared
    Range: CH4:0-100%, CnHm: 0-10% (Range can be configured according to user's actual needs)
    Resolution: CH4, CnHm: 0.01%
    Accuracy: CH4, CnHm: ≤ ± 2% FS
    Repeatability error: CO CO2CH4H2O2CnHm≤1%
    Optimal flow rate: 0.7~1.2 L/min
    Intake pressure: 2KPa~50KPa
    Sample gas requirements: dust-free, anhydrous, and oil-free
    Response time: T90 10s (NDIR)
    Signal output: 4-20mA analog output
    Working power supply: 220V
     

     
  • Introduction:
    The online infrared natural gas analyzer TY-6340 adopts internationally advanced NDIR non dispersive infrared technology, mainly used to measure the volume concentration and calorific value of gases such as CH4 and CnHm in natural gas. The online infrared natural gas calorific value meter developed by Wuhan Tianyu Intelligent Control adopts a standardized 3U chassis, with high measurement accuracy, simple structure, convenient maintenance, powerful software functions, strong scalability, and good on-site practicality. At present, it is widely used in gas appliance production enterprises and manufacturers, gas measurement and testing departments, energy conservation monitoring departments, scientific research, environmental protection and gas distribution industries, natural gas companies, liquefied gas plants, liquefied gas stations and other fields to measure the volume concentration and calorific value of different components in natural gas.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com