TS6110 ultraviolet fluorescence sulfur analyzer Introduction
The TS6110 UV fluorescence sulfur analyzer uses the volume difference method of sampling technology, which can effectively avoid the interference of air bubbles. The TS6110 total sulfur analyzer has three domestic firsts, a full-automatic liquid sampler, catalytic combustion technology, and air can be used as a carrier gas and a combustion gas. The TS6110 is a total sulfur analyzer that does not require argon and oxygen. Features
Catalytic Combustion Technology
Catalytic combustion technology, so that the sample can be completely transformed to avoid carbon deposits
Use of synthetic air as a carrier gas and combustion gas
At present, existing ultraviolet fluorescent sulfur analyzers on the market use Ar as a carrier gas and oxygen as a combustion-supporting gas. The TS6100 series UV fluorescent sulfur analyzer innovatively uses synthetic air as a carrier gas and combustion support, which avoids the problem of gas use in remote areas and effectively reduces the subsequent maintenance costs of the instrument.
Liquid autosampler
Adopting volume difference injection technology: can effectively avoid the interference of air bubbles
High and low sample analysis: different sample volumes can be used for different samples in the same batch of sample analysis
Two standard curve: Low concentration curve is used for low content samples, making low content samples more accurate. Technical Parameters
Meet the standards: SH / T0689-2000; ASTM D5453
Required gas: synthetic air (can be replaced by air generator)
Gas flow rate: flow rate range 350-450mgl / min (input pressure ≤0.12Mpa)
Injection method: manual injection or automatic liquid sampler
Furnace temperature: up to 1200 ° C
Temperature control accuracy: ± 1% FS
Combustion tube: quartz reaction tube filled with catalyst
Water removal mode: maintenance-free membrane dryer
Detector: High-sensitivity UV fluorescence detector
Accurate measurement range: 0.2-10000 (mg / kg)
Precision: 5ppm≤5%; 50ppm≤2%
Analysis time: 5min
Injection volume: up to 100 μL
Calibration method: external standard, straight or curved type, can be calibrated in sections
Introduction
The TS6110 UV fluorescence sulfur analyzer uses the volume difference method of sampling technology, which can effectively avoid the interference of air bubbles. The TS6110 total sulfur analyzer has three domestic firsts, a full-automatic liquid sampler, catalytic combustion technology, and air can be used as a carrier gas and a combustion gas. The TS6110 is a total sulfur analyzer that does not require argon and oxygen.