Position: Home > > Industry specific instrument > Coal industry special instruments > Other coal industry-specific > TRJC-9A intelligent fully automatic glial layer analyzer

TRJC-9A intelligent fully automatic glial layer analyzer

Product ID:HZMTOther0030

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberTRJC-9A
    Brand NameHBTIANRUN
    Payment TermsTT,PAYPAL
    TRJC-9A intelligent fully automatic glial layer analyzer
    characteristic:
    1. Automatic weight loading technology, without the need for manual weight mounting. No lever design, reducing volume by 1/3.
    2. Integrated ventilation design: The furnace body, fume hood, and fan are designed as a whole, with easy installation and no need for old-fashioned fume hoods.
    3. The entire process is automatically controlled without manual intervention, without the need for hanging volume sensors, automatic smoke exhaust, automatic alignment, automatic weight hanging, and automatic monitoring of the entire testing process. The equipment is designed strictly according to standards, and temperature control, measurement of X and Y values are all automatically completed by the computer.
    4. The intelligent robotic arm adopts an integrated design, with software integrated with ZJ experience measurement module, combined with power-off protection, automatic identification of wave peaks and valleys, and measurement functions to ensure accurate and reliable measurement data.
    5. The furnace body design changes the placement of furnace bricks from front to back to left and right, making practical operation more convenient. Reduce errors caused by machinery and greatly reduce the labor intensity of laboratory technicians in terms of operation.
    6. Automatic data saving: Data is saved using both PC and microprocessor to prevent data loss caused by short-term power outages and misoperations.
    7. Humanized operation interface: The PC interface simplifies complexity without complicated operation steps. Simply enter the coal sample name to automatically complete all the steps required for the experiment. All error messages are presented in Chinese, eliminating the hassle of having dedicated personnel review error codes every time they appear.
    8. Stable and reliable system design, with automatic alarm and power-off functions for measurement faults, temperature rise faults, and temperature control faults.
    Technical parameters:
    Temperature control range: (0-800) , accuracy: ± 3
    Power supply voltage: 220V, 50HZ
    Measurement accuracy: Y value error: When Y>20mm, the error is less than 2mm
    When Y<20mm, the error is<1mm
    X-value error: 3mm
    Temperature measuring component: K-type thermocouple
    Accuracy level: Level 0.5
    Pressure sensor: 0-20KG
    Displacement sensor: 0-200mm
    No leverage design, automatic loading of weights

  • characteristic:
    1. Automatic weight loading technology, without the need for manual weight mounting. No lever design, reducing volume by 1/3.
    2. Integrated ventilation design: The furnace body, fume hood, and fan are designed as a whole, with easy installation and no need for old-fashioned fume hoods.
    3. The entire process is automatically controlled without manual intervention, without the need for hanging volume sensors, automatic smoke exhaust, automatic alignment, automatic weight hanging, and automatic monitoring of the entire testing process. The equipment is designed strictly according to standards, and temperature control, measurement of X and Y values are all automatically completed by the computer.
    4. The intelligent robotic arm adopts an integrated design, with software integrated with ZJ experience measurement module, combined with power-off protection, automatic identification of wave peaks and valleys, and measurement functions to ensure accurate and reliable measurement data.
    5. The furnace body design changes the placement of furnace bricks from front to back to left and right, making practical operation more convenient. Reduce errors caused by machinery and greatly reduce the labor intensity of laboratory technicians in terms of operation.
    6. Automatic data saving: Data is saved using both PC and microprocessor to prevent data loss caused by short-term power outages and misoperations.
    7. Humanized operation interface: The PC interface simplifies complexity without complicated operation steps. Simply enter the coal sample name to automatically complete all the steps required for the experiment. All error messages are presented in Chinese, eliminating the hassle of having dedicated personnel review error codes every time they appear.
    8. Stable and reliable system design, with automatic alarm and power-off functions for measurement faults, temperature rise faults, and temperature control faults.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com