Introduction: The TQ-3A Hydrocarbon Analyzer is mainly used for the determination of "carbon" and "hydrogen" elements in coal and other organic materials. For coal, chemical, metallurgical, power and geological exploration and other departments of the laboratory. The basic principle is that the test sample in high temperature conditions, in the oxygen flow after the combustion of water and carbon dioxide, with water absorbent and carbon dioxide absorbent were absorbed. The percentages of carbon and hydrogen are calculated based on the weight gain of the absorbent. Features: TQ-3A hydrocarbon analyzer is in accordance with GB GB / T 476-2001 production of three furnace weight gravimetric hydrocarbon analyzer, which also meet the standard MT / M 228-2005 general technical requirements. The TQ-3A Hydrocarbon Analyzer consists of three main components: a high-temperature combustion unit, a gas purification system and an absorption system. See Test Flow Chart 1. The combustion device consists of three tubes of high temperature furnace and electrical control device. Hebi City days of Electronic Technology Co., Ltd. production of TQ-3A-type hydrocarbon analyzer using intelligent three-hysteresis-type temperature control digital table, high precision temperature control, digital instructions to adjust, with heating, over-temperature sound and light prompts, off Occasional digital code prompts and so on. The three intelligent digital meters respectively indicate and control the temperature of the three-stage furnaces. Technical Parameters: Furnace temperature: * One furnace: (850 ± 10) ℃, the second furnace: (800 ± 10) ℃, the third furnace: (600 ± 10) ℃. Burning tube: Dimensions: diameter Φ20 mm ~ 22mm, wall thickness 2mm, length 1100 ~ 1200mm. Material: 1Cr18Ni9Ti (stainless steel). Heating element: Φ0.6 ~ 1.0mm nickel chrome wire. Temperature components: two K-type thermocouple. Rated voltage: AC (220 ± 22) V (50 ± 1) Hz. rated power: A furnace: 1200W, the second furnace: 1500W, the third furnace: 800W. Intelligent digital display temperature measurement accuracy: ± 5 ℃.
Introduction: The TQ-3A Hydrocarbon Analyzer is mainly used for the determination of "carbon" and "hydrogen" elements in coal and other organic materials. For coal, chemical, metallurgical, power and geological exploration and other departments of the laboratory. The basic principle is that the test sample in high temperature conditions, in the oxygen flow after the combustion of water and carbon dioxide, with water absorbent and carbon dioxide absorbent were absorbed. The percentages of carbon and hydrogen are calculated based on the weight gain of the absorbent.