TIME® 2136 Ultrasonic Thickness Gauge Features
The instrument can determine whether the probe is inserted, can automatically identify the probe, and automatically calibrate the probe, or single-point calibration and multi-point calibration
The instrument can dynamically compensate for measurement errors caused by probe changes and coupling differences, improving measurement accuracy.
The instrument displays the coupling status in real time, which is convenient for users to adjust the coupling conditions. Backlight adjustment, high contrast and brightness, suitable for outdoor sunlight applications.
With scanning measurement mode, it can achieve a measurement rate of 20 times per second.
It has a variety of measurement modes (automatic, launch-echo, interface-echo-echo-echo), multi-echo through the coating thickness measurement function, measuring range 3-18mm (steel), can meet a variety of measurement needs.
Can store 500 thickness values.
The automatic storage function can be turned on to automatically store the last measured value in each coupled measurement process.
Probe can choose 2HMZ 5PФ10 / 90 7PФ6 10HMZ Technical Parameters
Model TIME®2136
Measuring range (steel) 0.65mm ~ 300.0mm
Thickness measurement across the coating Thickness of the paint 0-2mm Thickness of the steel 3-120mm
Indication error (steel) ZW5P, TSTU32: ± 0.10 (H <10.00mm), ± (1% H + 0.01) mm (H≥10.00mm)
5PФ10, 5PФ10 / 90, 7PФ6: ± 0.05 (H <10.00mm), ± (0.5% H + 0.01) mm (H≥10.00mm)
Repeatability (steel) ZW5P, TSTU32: 0.10mm; 5PФ10, 5PФ10 / 90, 7PФ6: 0.03mm
Indication stability (steel) ZW5P, TSTU32: 0.10mm; 5PФ10, 5PФ10 / 90, 7PФ6: 0.05mm
Indication error When measuring with 0.01mm resolution, the maximum indication error from the lower measurement limit to 10mm is ≤0.1mm, and the maximum indication error from 10mm to the upper measurement limit is ≤ ± (0.5% H + 0.05) mm.
Sound speed adjustment range (m / s) 1000m / s ~ 9999m / s
Thickness indication error of changing sound velocity The difference indication error should not exceed ± 0.5mm
Measurement Mode Auto, Transmit-Echo, Interface-Echo Echo-Echo
Scanning mode You can choose to open the scanning measurement mode 20 times per second
Measurement resolution 0.01mm, 0.001mm,
Display Backlit LCD display function
Special display Min, Max, Average
Alarm upper limit, lower limit, upper and lower limit alarm function
Two-point calibration with two-point calibration
Metric system Metric system display and switch
Battery level indicator Indicates battery level
Store 6 sound velocity values and 500 thickness values
Communication can be transferred to a personal computer via the USB communication port. The file can also be directly imported into Microsoft Excel format through macro commands. All alphanumeric data of file names and comments are directly input through the keyboard.
Automatic shutdown can choose to turn on the automatic shutdown function without action and measurement for 2 minutes
Automatic storage can choose to enable the function of automatically storing the last measured value of each coupling
Multilingual version Chinese and English version
Host size ≤128 × 62 × 26 (mm)
Host storage environment -25 ℃ ~ ﹢ 60 ℃ 90% RH
Power supply Two AA alkaline dry batteries
Working power 60mA (3.0V)
Standard configuration Host, 5PФ10 probe, 4mm steel calibration block, AA-type alkaline battery, coupling agent, host protective cover Manual warranty card
The TIME® 2136 Ultrasonic Thickness Gauge can determine whether a probe is inserted, can automatically identify the probe, and automatically calibrate the probe, or single-point calibration and multi-point calibration. The TIME® 2136 Ultrasonic Thickness Gauge displays the coupling status in real time, making it easy for users to adjust the coupling conditions. Backlight adjustment, high contrast and brightness, suitable for outdoor sunlight applications.