TE-BOD (6A) mercury-free differential pressure intelligent BOD analyzer
Introduction: The TE-BOD(6A) intelligent BOD analyzer adopts the national standard (HJ-505-2009) 5-day culture method, mercury-free differential pressure detection method, and is safe and reliable to use. The TE-BOD(6A) intelligent BOD analyzer contains 6 Each unit displays the test bit, and each unit test bit is tested separately. Each test bit has a built-in lithium battery. Power failure during the test will not affect the result. Information. Automatically complete the measurement process, no need for special care, safe and reliable, intelligent microcomputer control. Features: 1. Directly display the BOD detection data results of each channel; 2. Using a color display screen, the measured value is automatically displayed every day; 3. Use mercury-free differential pressure detection method to measure BOD in water, which is safe, reliable and easy to operate; 4. The microprocessor control system is used to automatically complete the measurement process without the need for special personnel to take care of it; 5. Adopt imported sensor, stable performance, less drift and accurate measurement; 6. The number of measurement samples is 1-6, and the start time of a single sample can be arbitrarily selected; 7. Equipped with built-in lithium battery for power supply, the power failure during the detection will not affect the results; 8. Large storage space, can store more than 100,000 test results; 9. The measurement process does not need to be supervised by a special person, not afraid of power failure, and the whole process is intelligently monitored. 10. It has the function of supporting continuous and intermittent stirring. Technical parameter: Instrument model: TE-BOD (6A) type Number of measurements: 6 groups Measuring principle: mercury-free differential pressure method Storage data: 5-7 days of data Measurement period: 5 days -7 days optional Measurement accuracy: ± 8% Culture bottle volume: 580mL Rated voltage: AC220V±10%/50-60HZ Measurement record: 5 minutes-3 hours/time Lower limit of determination: 2mg/L Rated power: 20W Culture temperature: 20±1℃ Measuring range: (0-4000) mg/L Stirring mode: support continuous and intermittent stirring
Introduction: The TE-BOD(6A) intelligent BOD analyzer adopts the national standard (HJ-505-2009) 5-day culture method, mercury-free differential pressure detection method, and is safe and reliable to use. The TE-BOD(6A) intelligent BOD analyzer contains 6 Each unit displays the test bit, and each unit test bit is tested separately. Each test bit has a built-in lithium battery. Power failure during the test will not affect the result. Information. Automatically complete the measurement process, no need for special care, safe and reliable, intelligent microcomputer control.