TD-2200 true density analyzer for Powder test

Product ID:WQmd021

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberTD-2200
    Brand NameYM
    Payment TermsT/T, paypal
    Analysis Principle :
        Gas replacement method is based on volume of the gas a substituted a liquid measurement sample the discharged . This method excludes the possibility of liquid immersion method pair sample is dissolved 's , having a the advantage of not damaging the sample of . , Application gas displacement of Archimedes principle ( density = mass / volume ) , using small molecule diameter inert gas under certain conditions of Bohr 's law (PV = nRT), accurate measurement of true volume the material being tested , to thereby obtain its true specific gravity .
    Technical parameters:
    Analysis Methods: gas replacement method
    Determination of Volume range : 0.01 ~ 100 cm3
    Analysis Number of warehouse : 2
    Precision degree : better than ± 0.06%
    Repeatability : better than ± 0.04%
    Gas path control system: six one of the the solenoid valve control module
    Software control system : INTERNET Remote Control
    Gas analysis : pure helium or nitrogen
    Sample analysis time: less than 8 minutes
     Instrument control : 10 -inch high resolution LCD touch screen
     Instrument volume : 680 * 360 * 290mm
    Features:
    1. The test of high precision, good accuracy, solve the problem of immersion method of sample dissolution.
    2. The whole testing process does not change the measured the physical properties of the sample.
    3. The test speed: 2-8 minutes to complete the whole test process.
    4. Applicable range: can be used to measure all kinds of powder, granule, block of solid samples and non-volatile liquid samples.
    5. Wide range of test: the density of the sample size is not restricted.
    6. The real full automatic operation: microprocessor control fully automatic operation, avoid the error caused by artificial operation.
    7. There are three different sizes (10, 50 and 135 cc) sample pool, can replace each other, to adapt to the measurement of different sample size range. Each sample pool of calibration data is stored in the permanent memory. 

  • Analysis Principle :
        Gas replacement method is based on volume of the gas a substituted a liquid measurement sample the discharged . This method excludes the possibility of liquid immersion method pair sample is dissolved 's , having a the advantage of not damaging the sample of . , Application gas displacement of Archimedes principle ( density = mass / volume ) , using small molecule diameter inert gas under certain conditions of Bohr 's law (PV = nRT), accurate measurement of true volume the material being tested , to thereby obtain its true specific gravity .

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com