TC-3010A Trace Element Analyzer Introduction: This instrument is a simplified instrument. Can simultaneously or independently automatically detect eight elements: zinc, iron, manganese, calcium, magnesium, cadmium, lead, and copper Equipped with maintenance free digital fully enclosed static mercury electrodes and imported glassy carbon electrodes. Desktop split design; Computer automatic control of supporting workstations; Support laboratory LIS system; There are multiple report formats available 2 sets of automatic current sharing and stability control systems; Automatic calibration instrument; Automatic detection and analysis; Automatic activation of elements; Automatic separation potential Technical parameters: Stable system: 6 sets of automatic current sharing and stable control systems Detection channels: dual channels for polarography and dissolution Detection methods: Polarographic analysis and differential potential dissolution method Analysis time: Polarography ≤ 8 seconds; Dissolution ≤ 70 seconds Blood collection volume: 20 μ l per channel, complete set of 40 μ l Multi element simultaneous detection: using potential separation and composite reagent technology, detecting 8 elements simultaneously without interference with each other Legal elements: zinc, iron, calcium, magnesium, manganese, selenium, cadmium, lead, copper (as evidenced by the registration form) Expansion project: > 100 Applicability: Specially designed for medical detection of trace elements in the human body Control technology: fully digital automatic control Applicable samples: peripheral blood, venous blood, urine, hair, semen, etc Pre processing: Using automatic element activation technology, no need to digest {hair and selenium elements excluded} Instrument calibration: automatic grading calibration {automatic work curve making} Analysis methods: including working curve method, standard addition method, and quality control calibration method Pollution prevention measures: closed detection technology Reference electrode: Using a maintenance free bio colloidal electrode Platinum electrode: Platinum wire electrode Working electrode: a fully enclosed, maintenance free static mercury electrode controlled by an electronic chip Lower limit of detection: Dissolution ≤ 0.01ug/L, Polarography ≤ 5x10-8mol/L Accuracy error: Dissolution RSD ≤ 3%; Polarographic RSD ≤ 1% Repeatability error: Dissolution CV ≤ 3%; Polarographic CV ≤ 1% Linear regression: R ≥ 0.9990 Overall structure: desktop split structure with workstation Workstation: providing computers Display: External 19 inch LCD display Printer: Color inkjet printer
Introduction: This instrument is a simplified instrument. Can simultaneously or independently automatically detect eight elements: zinc, iron, manganese, calcium, magnesium, cadmium, lead, and copper Equipped with maintenance free digital fully enclosed static mercury electrodes and imported glassy carbon electrodes. Desktop split design; Computer automatic control of supporting workstations; Support laboratory LIS system; There are multiple report formats available 2 sets of automatic current sharing and stability control systems; Automatic calibration instrument; Automatic detection and analysis; Automatic activation of elements; Automatic separation potential