Introduction: T931 Coulometric Moisture Analyzer adopts Karl Fischer Coulomb method, which can be used to accurately analyze the moisture in solids and liquids, with reliable results and wide measurement range (0.001%-100%). Equipped with a 10-inch large touch screen, easy to operate. Multiple safety designs are adopted to avoid operator contact with toxic reagents. Can be widely used in petroleum, chemical, food, cosmetics, medicine and other fields. Features: 1. Humanized human-computer interaction design, close to the daily use of mobile phones and tablets, easy to operate, flexibly click the parameters that need to be set and changed, and swipe left and right to view richer data content to improve work efficiency. 2. Modular menu bar, can quickly and accurately enter each interface. 3. In the sample test, the test curve, instrument parameters, analysis results and other information are displayed in real time, and the entire titration process can be monitored in real time. 4. Various result units are displayed: mg, %, ppm, H2O, mL, mg/mL, mg/g, etc. 5. With data retrieval function, you can quickly check historical data. 6. The V-T and E-T map forms can be switched between analysis experiments at any time, and the curve can be manually enlarged or reduced. 7. 8G mass storage space, which can be used to store experimental methods, data, traceability files, etc. 8. The automatic replacement of reagents can be realized without opening the reaction cup, preventing moisture in the air from entering the titration cup, and the equilibration time after replacing the reagent is shorter, reducing the contact between operators and toxic reagents. 9. Various specifications of the volume method injection port, Coulomb method puncture resistant injection port, to meet the injection methods of different samples. 10. Equipped with a waste liquid overflow prevention device to prevent the waste liquid bottle from overflowing when it is full. 11. Standard magnetic stirrer, support manual and automatic stirring. 12. The plug-in reagent bottle anti-falling rack can be freely combined and compatible with 250mL, 500mL and 1000mL reagent bottles. Technical parameter: Determination method: Karl Fischer volume method; Karl Fischer coulomb method Moisture measurement range: 0.001%-100% moisture Recommended moisture measurement range: 0.1%-100% moisture; 10μgH2O~200mgH2O (Karl Fischer Coulomb method) Polarization current range: 1~24μA Polarization current resolution: 0.01μA Polarization Current Error Range: 0.05μA Voltage range: 0-1999mV Voltage Resolution: 0.1mV Voltage error range: ±0.2mV Number of methods: 150 Export format: Excel, PDF Display mode: 10-inch TFT capacitive screen The map shows: E-T, V-T; E-T (Karl Fischer Coulomb method) Drift correction function: manual, automatic, off Compliant with FDA21 CFR pat11: Yes Audit Trail: Yes Authority management: four levels of authority (super administrator, supervisor, operator, IT) Number of users: 30 Storage space: 8G Sample cell: 120mL; 200mL (Karl Fischer Coulomb method) Communication interface: WiFi, USB, Ethernet, RS232, BNC Stirring method: magnetic stirring Available Printers: Wireless Laser Printers, Wired Micro Printers Power supply: Input voltage 100-240V ±10% Input frequency 50-60Hz Output voltage 24VDC
Introduction: T931 Coulometric Moisture Analyzer adopts Karl Fischer Coulomb method, which can be used to accurately analyze the moisture in solids and liquids, with reliable results and wide measurement range (0.001%-100%). Equipped with a 10-inch large touch screen, easy to operate. Multiple safety designs are adopted to avoid operator contact with toxic reagents. Can be widely used in petroleum, chemical, food, cosmetics, medicine and other fields.