1 Sales SYN5106 high precision clock tester,Manufacturer

SYN5106 high precision clock tester

Product ID:CLQTsjpljly021

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberSYN5106
    Brand NameXATBDZKJ
    Payment TermsT/T, paypal
    Product overview:
    SYN5106 high precision tester is a portable time frequency comprehensive test  quipment carefully designed and developed by xi 'an synchronous electronic technology co., LTD. Equipped with OCXO thermostatic crystal oscillator and GPS beidou dual mode built-in antenna, it receives GPS (global positioning system) and beidou ii satellite timing signal, and generates extremely accurate time signal. Taking this as a reference, the accuracy of various input time frequency signals is accurately measured in real time, which provides an effective and convenient solution for on-site detection, verification and acceptance of time synchronization devices and timely integrated equipment.
    Product functions:
    1) in terms of structural design, the integration of time standard source and test result display function can be achieved, so that the test project can be conveniently and accurately completed in a portable intelligent instrument;
    2) portable and mobile, it can be used in both the field and the detection mechanism;
    3) the output time signal can be compared with a more advanced standard time source to calibrate the accuracy level of the tester.
    It can also be used to provide high-precision time signal for on-site equipment in need;
    4) the measurement result data is automatically exported to the computer;
    5) it is powered by 6AH battery.
    Product features:
    1) high precision, high cost performance;
    2) complete functions and reliable performance;
    3) automatic calculation of frequency comparison value;
    4) high precision, high reliability, convenience and intuition.
    Typical applications:
    1) power system, measurement and calibration departments and scientific research institutes;
    2) it can be used for laboratory testing and calibration of time-frequency products;
    3) it can be used for the inspection and testing of time and frequency products by manufacturers;
    Technical indicators:
    Input signal GPS/ beidou ii generation dual mode receiver Frequency point L1B1
    Timing accuracy ≤30ns
    Tracking sensitivity -160dBm
    Frequency measurement Way 1
    Frequency range 100μHz25MHz(pulse)
    Certainty of measurement ≤2E-8/1s(equal precision measurement)
    Time difference measuring Way 2
    Trigger edge Rising / descending edge
    Measurement content Single channel measurement / dual channel measurement / 1PPS measurement
    Accuracy of measurement ±(F0×T020ns)
    Measuring range 10ns99 999 999 999 990ns
    Resolution 10ns
    Measurement of timing error (watt-hour meter) Way 1
    Electrical level Watt-hour meter output level
    Frequency 1Hz
    Measurement content Accuracy, PPM (1/1000000 accuracy), s / r d (day difference), s / m (month difference), s / r y (year difference)
    Measuring gate 1s10s20s60s100s1000s
    Certainty of measurement ≤ 2E-8/1s (equal precision measurement)
    Resolution ratio 10ns
    Noncontact measurement(option) Way 1
    Frequency 32.768khz
    Measurement content Accuracy, PPM (1/1000000 accuracy), s / r d (day difference), s / m (month difference), s / r y (year difference)
    Measuring gate 1s10s20s60s
    Certainty of measurement ≤0.2ppm
    Output signal 1 PPS  output Way 1
    Electrical level TTL
    10 MHZ output Way 1
    Frequency accuracy ≤ 1E-8 (factory accuracy)
    Serial port output Way 1-way DB9
    content Output test content
    USB storage (reserved) Plug in usb flash drive for automatic storage
    Environmental features Working temperature 0~+50
    Relative humidity ≤90%40
    Storage temperature -30~+70
    Power supply DC 5v, power less than 10W, battery: 6AH
    Case size Portable case 410mm*340mm*130mm
     


     
  • Product overview:
    SYN5106 high precision tester is a portable time frequency comprehensive test  quipment carefully designed and developed by xi 'an synchronous electronic technology co., LTD. Equipped with OCXO thermostatic crystal oscillator and GPS beidou dual mode built-in antenna, it receives GPS (global positioning system) and beidou ii satellite timing signal, and generates extremely accurate time signal. Taking this as a reference, the accuracy of various input time frequency signals is accurately measured in real time, which provides an effective and convenient solution for on-site detection, verification and acceptance of time synchronization devices and timely integrated equipment.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com