Introduction: The SY-2D tablet four-purpose tester is used to test the hardness, friability, disintegration time limit and dissolution rate of the tablet, and the various performance tests of the tablet are integrated in one instrument. SY series tablet four-purpose tester is the best instrument for scientific research units, colleges and universities, drug inspection departments and pharmaceutical factories to test drugs. Features 1. Simple and user-friendly operation interface and method. 2. Four functions: dissolution rate, disintegration time limit, tablet hardness, tablet brittleness, high efficiency and convenience. 3. Smaller volume, reducing the occupied area of the laboratory workbench. 4. One basket rod or paddle rod can be installed, one dissolution vessel and two flat-bottomed beakers can be placed. 5. The transparent lens window above the hardness testing chamber is clear and intuitive. 6. Accurate rotation speed, stable operation, low energy consumption and high reliability. 7. With fault self-diagnosis function. Technical parameter: 1. Dissolution Swing amplitude of stirring paddle: ≤0.5 mm Basket swing range: ≤1.0 mm Deviation between the rotating rod and the dissolution vessel axis: ≤2.0 mm Speed setting range: 25~250 RPM Steady speed error: ≤±1 % Temperature adjustment range: room temperature~45.0℃ Temperature Resolution: 0.1 ℃ Temperature control accuracy: ≤±0.5 ℃ Dissolution vessel specifications: height 185mm, volume 1000ml Number of Dissolution Vessels: 1 2. Disintegration time limit Basket lifting frequency 30~32 times/min Basket lifting amplitude: 55mm±1mm The minimum distance from the screen to the bottom of the cup: 25mm±2mm Screen aperture: 2mm (optional) Temperature adjustment range: room temperature~45.0℃ Temperature Resolution: 0.1 ℃ Temperature control accuracy: ≤±0.5 ℃ Flat bottom beaker volume: 1000ml Number of flat-bottomed beakers: 2 3. Tablet hardness Measuring range: hardness 10-200N, tablet diameter 2-25mm Resolution: 0.01N Accuracy: ±1.5%±1digit Hardness unit of measure: N/kg (optional) Measurement method: automatic single / continuous multiple 4. Tablet friability Drum size: about 286mm inner diameter, 39mm deep Default RPM: 25 RPM Default laps: 100 laps Setting range of laps: 1~999 laps Number of drums: 1 5. Power supply: AC220V±10%, 50Hz
Introduction: The SY-2D tablet four-purpose tester is used to test the hardness, friability, disintegration time limit and dissolution rate of the tablet, and the various performance tests of the tablet are integrated in one instrument. SY series tablet four-purpose tester is the best instrument for scientific research units, colleges and universities, drug inspection departments and pharmaceutical factories to test drugs.