Main features: 1. It is suitable for fluorescence and light absorption detection, and has various fitting curves for analysis; 2. Suitable for testing the activity of protease, kinase, phospholipase, NADH and GST; 3. It is suitable for quantitative analysis of proteins, and supports UV, NanoOrange, Bradford, Lowry and other methods. 4. Applicable to DNA/RNA analysis; 5. Applicable to reactive oxygen analysis and cAMP analysis; 6. Applicable to cell proliferation and cytotoxicity test, MTT, XTT; 7. Applicable to the analysis of microbial growth, endotoxin and bacterial concentration; 8. Suitable for molecular probe experiment; 9. Uv and fluorescence spectra can be scanned; 10. The excitation and emission components are all high resolution grating monochromator, and the optimal excitation and emission wavelength can be set. 11. The built-in grating monochromator has a wavelength range of 190nm to 1000nm and has good adaptability. 12. Wavelength resolution: 1nm, wavelength repeatability up to 0.2nm; 13. Dynamic analysis model; 14 and has incubated with the temperature control system, temperature is 65 ℃, to adapt to the high temperature test; 15. It has the function of shock mixing with micro-orifice plate, and no need to use external shaking table; 16. Xenon lamp light source with high intensity and stable luminescence; 17. It has sample detection detector and reference detector, which can detect accurately; 18. A microporous plate analysis workstation with strong data analysis capability; 19. Equipped with the function of instrument parameter setting and instrument self-inspection, highly automatic; 20. USB data interface is used to facilitate instrument control and data transmission; 21. All-chinese interface, suitable for the use and teaching of domestic operators; 22. The performance is not lower than that of the imported similar products, with high cost performance; Main indicators: Fluorescence performance: Detector: photomultiplier tube (PMT) Excitation wavelength range: 190nm-1000nm; Emission wavelength range: 270nm-850nm; Wavelength resolution: 1nm; Wavelength bandwidth: 10, 20nm optional; Wavelength accuracy: <0.2nm; Fluorescence sensitivity: Top reading < 0.5fmol (FITC/ hole to 384 plate) Bottom reading < 5fmol (FITC/ hole -- plate 384) Detection order: Top reading > 6 orders of magnitude (FITC/ hole to 384 board) Bottom reading > 5.5 orders of magnitude (FITC/ hole to 384 board) Reading mode: top reading + bottom reading Petri dish module: no Optical absorption performance: Detector: photocell Wavelength range: 190nm-1000nm Wavelength accuracy: plus or minus 1.0nm Wavelength repeatability: <0.2nm Linear range: 0-4abs (96 holes, 450nm), plus or minus 2% Whole plate repeatability: extreme value < 0.006 Test module: no General features: Light source: xenon lamp Temperature control: (+ 2 ℃) at room temperature to 65 ℃ Mode of oscillation: linear, cross, circular Amplitude of oscillation: high, medium and low Plate type: 96, 384 holes (other holes can be customized).
Main features: 1. It is suitable for fluorescence and light absorption detection, and has various fitting curves for analysis; 2. Suitable for testing the activity of protease, kinase, phospholipase, NADH and GST; 3. It is suitable for quantitative analysis of proteins, and supports UV, NanoOrange, Bradford, Lowry and other methods. 4. Applicable to DNA/RNA analysis; 5. Applicable to reactive oxygen analysis and cAMP analysis; 6. Applicable to cell proliferation and cytotoxicity test, MTT, XTT; 7. Applicable to the analysis of microbial growth, endotoxin and bacterial concentration; 8. Suitable for molecular probe experiment; 9. Uv and fluorescence spectra can be scanned; 10. The excitation and emission components are all high resolution grating monochromator, and the optimal excitation and emission wavelength can be set. 11. The built-in grating monochromator has a wavelength range of 190nm to 1000nm and has good adaptability. 12. Wavelength resolution: 1nm, wavelength repeatability up to 0.2nm; 13. Dynamic analysis model; 14 and has incubated with the temperature control system, temperature is 65 ℃, to adapt to the high temperature test; 15. It has the function of shock mixing with micro-orifice plate, and no need to use external shaking table; 16. Xenon lamp light source with high intensity and stable luminescence; 17. It has sample detection detector and reference detector, which can detect accurately; 18. A microporous plate analysis workstation with strong data analysis capability; 19. Equipped with the function of instrument parameter setting and instrument self-inspection, highly automatic; 20. USB data interface is used to facilitate instrument control and data transmission; 21. All-chinese interface, suitable for the use and teaching of domestic operators; 22. The performance is not lower than that of the imported similar products, with high cost performance;