Brief introduction:
My company reference GB11914-89 method to launch this instrument. Replace the high power electric furnace with electric heater temperature control heating, air cooling instead of condensation water, automatic temperature control, automatic slightly boiling state 120 minutes countdown, digestion technology means such as automatic stop over, implements the operation method and national standard method for the echo, a key operation, automatically, saving energy and reducing consumption, use simple easy to operate, but also avoids the non technical disputes caused by national standard method of measurement of COD. Features:
1. Eliminate holes with high temperature resistant to strong acid and alkali corrosion resistance of graphite holes, heating more balanced use more security;
2. The digestion program adopts PID temperature control, set temperature and real temperature deviation plus or minus 2 ℃
3. Use a body around the heating mode, make digestion sample is heated more evenly, dissolve more thoroughly;
4.12 a resolution hole are separately set heating device, each hole digestion temperature can be monotonous single control;
A key to achieve 5. Digestion, digestion process is done automatically, eliminate over power over heating;
6. The instant dissolution of the hole in the process of digestion temperature and reflux time synchronization LCD screen display, convenient to monitor the be clear at a glance;
7. Adopts air cooling instead of the traditional tap water cooling method, more energy conservation and environmental protection;
8.300 ml large-capacity digestion bottle design, no need pipetting, direct titration; Technical indicators:
Model: 106
Display mode: color screen
Temperature control precision: + / - 1 ℃;
Parallelism between hole temperature: + / - 1 ℃;
Design temperature: 0-300 ℃;
Dispelling bottle capacity: 350 ml
Temperature control: 0-250 ℃;
Time control: 0-150 min is adjustable, can be a single control
Dispelling bottle size: 58 mm * 200 mm
Rated power: 2400 w
Digestion element: graphite holes
Dimension: 51 * 50 * 21
Heating time: 15-20 min
Cooling: air cooling
Sample quantity: 12
Brief introduction:
My company reference GB11914-89 method to launch this instrument. Replace the high power electric furnace with electric heater temperature control heating, air cooling instead of condensation water, automatic temperature control, automatic slightly boiling state 120 minutes countdown, digestion technology means such as automatic stop over, implements the operation method and national standard method for the echo, a key operation, automatically, saving energy and reducing consumption, use simple easy to operate, but also avoids the non technical disputes caused by national standard method of measurement of COD.