1 Sales ST1900 automatic permanganate index tester,Manufacturer
Position: Home > > Environmental monitoring and analysis > Water organic pollutants > permanganate index > ST1900 automatic permanganate index tester for Water pollution detection

ST1900 automatic permanganate index tester for Water pollution detection

Product ID:HSYJgm013

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberST1900
    Brand NameJINANSHENGTAI
    Payment TermsT/T, paypal
    ST1900 automatic permanganate index tester
     
    Introduction:
    It is suitable for the determination of drinking water, source water and surface water. The measurement range is 0.05-5.0mg/L. For water with heavy pollution, less water samples can be taken and measured after proper dilution.
    According to the standard:
    GB11892-89 "Water Quality Determination of Permanganate Index"
    GB/T5750.7 "Comprehensive Index of Organic Matter in Drinking Water Standard"
    ISO8467-1986 "Water Quality Determination of Permanganate Index"
    Equipped with 29 intelligent autosampler, the sample does not need to be weighed, automatic quantification-automatic reagent addition-automatic water bath digestion-automatic titration-automatic end point recognition-automatic calculation results-data printing, automatic upload and other functions. The whole process only needs to manually put the sample into the sample tray, and other tasks are automatically completed by the instrument. The test results can be uploaded as you like with one button. Your work is simpler and easier:
    Features:
    1) The 29-position automatic sampling tray, the sample to be tested does not need to be weighed, and the equipment automatically transfers the sample to the sample area quantitatively. The sampler has a pipeline cleaning function and will not cause cross contamination.
    2) Fully automatic three-axis robot motion system, which quickly realizes the transfer of the sample to be tested from the test area to the digestion area and the titration area;
    3) The sample automatically adds sulfuric acid and potassium permanganate solution to the reagent addition area. If the sample has been acid added, click "Cancel acid addition" in the system operation area;
    4) Automatic water bath digestion. After the digestion is over, use potassium permanganate to drip back excess sodium oxalate in a constant temperature environment (60-80 degrees);
    5) The titration end point is automatically determined, using advanced visual sensing technology higher than the human eye, and the titration end point is automatically determined through color changes;
    7) The instrument adopts a PLC control system, which makes the instrument more stable; the system automatically completes the entire experiment process and automatically outputs the experimental result data, which is convenient for the statistics of the experimenter;
    8) According to the national standard, the boiling water bath heating method is adopted to make the sample heated more evenly. At the same time, it has the function of automatic water replenishment to ensure that the sample to be tested is completely immersed in the boiling water bath.
    9) The high-precision syringe pump is used for titration and sample addition, and the accuracy of titration and sample addition reaches 5‰, which reduces the influence of experimental titration errors on the results.
    10) Automatically realize the safety monitoring of the reagent liquid volume, and display the reagent liquid level in real time.


     
     
  • Introduction:
    It is suitable for the determination of drinking water, source water and surface water. The measurement range is 0.05-5.0mg/L. For water with heavy pollution, less water samples can be taken and measured after proper dilution.
    According to the standard:
    GB11892-89 "Water Quality Determination of Permanganate Index"
    GB/T5750.7 "Comprehensive Index of Organic Matter in Drinking Water Standard"
    ISO8467-1986 "Water Quality Determination of Permanganate Index"
    Equipped with 29 intelligent autosampler, the sample does not need to be weighed, automatic quantification-automatic reagent addition-automatic water bath digestion-automatic titration-automatic end point recognition-automatic calculation results-data printing, automatic upload and other functions. The whole process only needs to manually put the sample into the sample tray, and other tasks are automatically completed by the instrument. The test results can be uploaded as you like with one button. Your work is simpler and easier:
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com