ST-1563 Fully Automatic Trace Carbon Tester Introduction
ST-1563 Trace Carbon Detector is designed and manufactured in accordance with GB / T17144 standard. It has beautiful appearance and convenient operation. It is used to determine the residues formed by evaporation and pyrolysis of petroleum products under specified conditions. It is suitable for detection. Its residual carbon range is 0.10% (m / m) to 30.0% (m / m) for petroleum products. The measurement results are equivalent to those of Kang type residual carbon (GB / T 268); it is also suitable for detecting residual carbon values below 0.10% (m / m), a petroleum product composed of fractions, suitable for petrochemical, building materials, metallurgy, scientific research units, commodity inspection and university laboratories. Features
1.Only a small amount of sample is required for testing
2.Automatic control of temperature rise and flow, real-time display of experimental process, automatic conversion control of ventilation flow, and automatic constant temperature holding time
3.Automatic heating and temperature control during experiment, automatic switching of nitrogen flow rate and automatic stop
4.The sample tube can be edited and input, and the mass of the sample can be automatically calculated by the instrument.
5.Nitrogen will be cut off automatically when the instrument is turned off, and there will be no inadvertent leakage of nitrogen.
9.Simultaneous determination of 12 samples, automatic storage of 1500 records for easy inquiry
10.Full Chinese / English interface display (optional) Technical Parameters
Adaptation standard: GB / T17144
Temperature control point: 500 ℃
Temperature control accuracy: ± 2 ℃
Heating power: 1500W
Working pressure: 0.15Mpa
Air source pressure: the minimum pressure is 2MPa, the maximum pressure is 0.5Mpa
Flow range: 100ml ~ 1000ml / min (adjustable)
Nitrogen flow: 150mL / min and 600mL / min (automatic switching)
Heating rate: 10 ~ 15 ℃ / min
Number of samples: 12
Power source: 220V ± 10% 50Hz
Ambient temperature: 5 ℃ ~ 45 ℃
Relative humidity: 10% ~ 80% Rh
Machine power: 1600W
Dimensions: 382 × 408 × 575mm
Introduction
ST-1563 Trace Carbon Detector is designed and manufactured in accordance with GB / T17144 standard. It has beautiful appearance and convenient operation. It is used to determine the residues formed by evaporation and pyrolysis of petroleum products under specified conditions. It is suitable for detection. Its residual carbon range is 0.10% (m / m) to 30.0% (m / m) for petroleum products. The measurement results are equivalent to those of Kang type residual carbon (GB / T 268); it is also suitable for detecting residual carbon values below 0.10% (m / m), a petroleum product composed of fractions, suitable for petrochemical, building materials, metallurgy, scientific research units, commodity inspection and university laboratories.