ST-1560 automatic opening and closing mouth flash point tester Introduction
ST-1560 open-closed flash point tester, in accordance with GB / T3536, GB / T261, can measure open and closed flash points simultaneously. The instrument is controlled by a microcomputer and embedded in a mini-type operating system. The entire operation and experiment process is fully automated, and the working process is automated. It has the characteristics of high measurement accuracy, good repeatability, stable and reliable performance, and simple operation. Widely used in petroleum, chemical, power, commodity inspection, colleges, scientific research and other departments. Features
1.Color LCD touch screen, intuitive and convenient operation
2.The host can control multiple test furnaces to test multiple samples at the same time.
3.Detection, cover opening, ignition, alarm, cooling, printing, the entire experimental process is automatically completed
4.Platinum heating wire or gas ignition can be selected
5.Automatic detection of atmospheric pressure and correction of test results
6.Using high-power high-frequency switching power supply heating technology, high heating efficiency, adaptive PID control algorithm, automatic adjustment of heating curve
7.Automatic stop detection and alarm when temperature exceeds the value
8.Temperature-compensated hundred-year calendar clock, accurate travel time, automatically record the date and time of measurement, can run for more than 10 years in the state of power failure
9.Thermal mini printer, make printing more beautiful and faster, with offline printing function
10.Achieve full Chinese / English interface display Technical Parameters
Applicable standards: GB / T3536, ASTMD92, GB / T261, ASTMD93
Temperature range: room temperature to 400 ° C
Accuracy: 0.5%
Resolution: 0.1 ℃
Repeatability: Opening: in accordance with GB / T3536
Closed mouth: accord with GB / T261
Ignition mode: electric ignition, gas ignition (optional)
Power: ≤400W
Heating rate: in line with national standards, EU standards
Ambient temperature: 5 ℃ ~ 45 ℃
Relative humidity: 10% ~ 80% Rh
Power supply voltage: 220V ± 10% 50Hz
Weight: 26KG
Introduction
ST-1560 open-closed flash point tester, in accordance with GB / T3536, GB / T261, can measure open and closed flash points simultaneously. The instrument is controlled by a microcomputer and embedded in a mini-type operating system. The entire operation and experiment process is fully automated, and the working process is automated. It has the characteristics of high measurement accuracy, good repeatability, stable and reliable performance, and simple operation. Widely used in petroleum, chemical, power, commodity inspection, colleges, scientific research and other departments.