SPE 432 Automatic Solid Phase Extraction Instrument Introduction
The automatic solid-phase extraction instrument SPE432 is designed according to the requirements of high-throughput laboratories. It has the characteristics of small size and good versatility. It is widely used in the extraction of pesticide residues, veterinary drug residues and other chemical residues. It can protect the columns and detectors in valuable instruments such as GC / MS, GC and HPLC from contamination, so that the equipment can maintain high sensitivity for a long time, accelerate the sample processing speed, thereby increasing sensitivity and reducing the minimum detection limit. Features
Small volume and high throughput:
1. Compact design, small spot area, specially designed for high-throughput laboratories, small size can be placed in a fume hood.
2. Number of channels: 4 channels / (can be upgraded to 6 channels, please consult us for details).
3. Processing digits: standard 32 bits, optional 64 bits.
Generality:
1. Laboratory 15ml and 50ml centrifuge tubes can be placed on sample racks and collection racks. There is no need to customize samples and collection racks according to different specifications of test tubes.
2. The collection tube is the same as the EVA 32 nitrogen blowing concentrator, and the concentration step can be performed without sample transfer.
Ease of use:
1. The design of the mobile sample rack and collection rack can be transferred with the sample tube and the collection tube as a whole. It is not necessary to place the sample tube and the collection tube on the instrument in turn, saving time and effort.
2. Open platform, 15mL, 50mL sample rack, collection rack, 1-12mL extraction block, can be used in any combination according to the needs of the method without repositioning. Technical Parameters
Materials in contact with solvents: resistant to organic solvents
Loading volume: 0-300ml
Number of samples: Process 1 to 4/6 samples at a time, up to 96 consecutive samples
Eluent solvents: 6 different solvents
Flow rate control: 0.1 ~ 100mL / min
Extraction type: universal membrane
Number of channels: multi-channel
Degree of automation: fully automatic
Introduction
The automatic solid-phase extraction instrument SPE432 is designed according to the requirements of high-throughput laboratories. It has the characteristics of small size and good versatility. It is widely used in the extraction of pesticide residues, veterinary drug residues and other chemical residues. It can protect the columns and detectors in valuable instruments such as GC / MS, GC and HPLC from contamination, so that the equipment can maintain high sensitivity for a long time, accelerate the sample processing speed, thereby increasing sensitivity and reducing the minimum detection limit.