Instrument Description : Atomic absorption spectrophotometer important means of quantitative analysis as a routine amount , trace metals and semi-metallic elements , because of its good detection accuracy and high sensitivity , rapid analysis and so on. In all areas of biotechnology, food , geology, metallurgy , building materials , medicine , environment, petrochemicals , agriculture, etc. are widely used . SP-3520AA / SP-3530AA atomic absorption spectrophotometer using expert database information system , to provide you with fast and accurate detection information and detection methods , which greatly reduces the difficulty of the work of analysts , to avoid human error in the operation to ensure that the analysis accuracy. Windows based operating platform Win-AAS workstation software , user-friendly, easy to operate in full compliance with the PC operating practices, without professional training. Main features: First, the total reflection optical system , the whole band achromatic , after adjusting the focus point is good, replace any wavelength , the focal point
Were no longer change . Benefits: a guarantee instrument's measurement accuracy and precision ; 2 replace any hollow cathode lamp
After having to adjust the focus point .
Second, the unique design of the all-titanium burner , combustion smooth , fast thermal equilibrium .
Three , eight lighthouse automatic control system, fully adjustable hollow cathode lamp to the optimum position .
Fourth, the graphite furnace contains three heating modes : Normal temperature , light control power to heat up, when the control power to heat up. Technical parameters: Performance Specifications
Optical system: anaberrational C-T -type monochromator device
Wavelength range : 190.0-900nm automatically adjusted
Wavelength Accuracy : ±0.20nm ( automatic calibration system )
Wavelength Repeatability : 0.10nm
Spectral Bandwidth : 0.1nm, 0.2nm, 0.7nm, 1.4nm automatically switch
Resolution : better than 0.3nm
Baseline Drift : 0.003A / 30min Flame analysis
The detection limit (Cu): 0.006ug / ml
Characteristic concentration (Cu): 0.03ug / ml / 1%
Burner : titanium burner (100mm)
Precision : RSD≤1%
Sprayers : efficient glass atomizer
Spray chamber : corrosion-resistant material spray chamber
Safety measures: with a variety of automatic protection function Graphite furnace analysis
Characteristic quantities (Cd): ≤0.6 × 10-12g
The detection limit (Cd): ≤1.0 × 10-12g
Precision : RSD≤3%
Background Correction : deuterium background correction to correct 1A background
Background correction capability : ≥50 correction capability Data Processing
Concentration is calculated : the standard curve method ( 6 kinds of linear or non-linear curve ) , standard
Quasi- addition method, interpolation
Repeat measurement times : 1-30 times , calculating the average , standard deviation, and given phase standard deviation
Instrument Description : Atomic absorption spectrophotometer important means of quantitative analysis as a routine amount , trace metals and semi-metallic elements , because of its good detection accuracy and high sensitivity , rapid analysis and so on. In all areas of biotechnology, food , geology, metallurgy , building materials , medicine , environment, petrochemicals , agriculture, etc. are widely used . SP-3520AA / SP-3530AA atomic absorption spectrophotometer using expert database information system , to provide you with fast and accurate detection information and detection methods , which greatly reduces the difficulty of the work of analysts , to avoid human error in the operation to ensure that the analysis accuracy. Windows based operating platform Win-AAS workstation software , user-friendly, easy to operate in full compliance with the PC operating practices, without professional training.