SP-3420A gas chromatograph Cost effective

Product ID:FSqi030

Price: Please inquire PDF Format
Supply Ability:20sets/mon
Port:Shenzhen
share:
  • Product Introduction
  • Consulting
  • Model NumberSP-3420A
    Brand NameYIMA
    Payment TermsT/T, paypal
    Features
    1. Continuous monitoring instruments working condition, according to the fault information prompts the operator to maintain their own equipment.
    2. Over-temperature protection ; open or shorted probe tips ; TCD hot filament protection ; FID flame tips ; FPD light leakage protection ;
    3. interactive form of input parameters , there are prompts ; can store four analytical methods , the method can automatically link ;
    Autosampler can be connected ;
    3. A variety of injection unit Optional: stigma packed column injector ; rapid vaporization of a packed column injector ; automatic and manual gas sampling valve ; Headspace Sampler ; thermal desorption injector ;
    4. A variety of detector options : TCD; FID; ECD; FPD; TSD, up to install two thermal conductivity detector or three different detectors .

    5. Amplifier Time Programming: each detector amplifiers with a fifth-order time programming function can automatically change the attenuation of the output signal range and polarity.
    6. External Event Time Programming: four external events with twenty -order time programming, can be completed in three autosampler valves , control valves and automatic switching blowback valve ; may signal conversion between the two detectors .
    7. The user needs to be made specific gas chromatography for various purposes , multi-dimensional chromatography.

    Technical Specifications
    Oven : Temperature range: room temperature ~ 400 ; after dual door opener , dropped to 50  time is less than 5 minutes from 250 ; temperature program : 16-step ; heating rate of 0.1  ~ 50 / min .
    Note sampler box : room temperature ~ 400 

    Thermal conductivity detector (TCD)
    Maximum set temperature : 350 

    Sensitivity ≥10000mv • ml / mg built-in amplifier ;
    Linear range: 105 Current range : 50 ~ 400mA
    Hot wire protection : He or H2 carrier gas when there is a problem in the current closed within four minutes .

    Flame ionization detector (FID)
    Maximum set temperature : 400 

    Detection limit : ≤3.1 × 10-12g / s (n-C16); linear range : 107
    Flameout Tip : always automatically detect the boot
    Electron capture detector (ECD)
    Maximum set temperature : 400 

    Detection limit : ≤1.6 × 10-14g / s (γ- 666); linear range : 104
    Sources : 11mC63 Ni

    Flame photometric detector (FPD)
    Maximum set temperature : 400 

    The detection limit : [P] ≤1.1 × 10-12g / s ( methyl parathion )
                   [S] ≤6 × 10-11g / s ( methyl parathion )
    Linear range : [P]: 105; [S]: 103
    Double Flame way : for large sample size to detect or trace into the sample
    Single Flame : can improve the sensitivity of detection of sulfur
    Direct output : For phosphorus or sulfur detection
    Square root output : For sulfur detection
    Light leakage protection : automatically cut off when high pressure leaked current ≥12μA

    Thermionic detector (TSD)
    Maximum set temperature : 400 

    Detection limit : [N] ≤2 × 10-13g / s ( azobenzene )
                   [P] ≤1 × 10-13g / s ( malathion )
    Linear range : [N]: 105; [P]: 104

     

  • Features
    1. Continuous monitoring instruments working condition, according to the fault information prompts the operator to maintain their own equipment.
    2. Over-temperature protection ; open or shorted probe tips ; TCD hot filament protection ; FID flame tips ; FPD light leakage protection ;
    3. interactive form of input parameters , there are prompts ; can store four analytical methods , the method can automatically link ;
    Autosampler can be connected ;
    3. A variety of injection unit Optional: stigma packed column injector ; rapid vaporization of a packed column injector ; automatic and manual gas sampling valve ; Headspace Sampler ; thermal desorption injector ;
    4. A variety of detector options : TCD; FID; ECD; FPD; TSD, up to install two thermal conductivity detector or three different detectors .

    5. Amplifier Time Programming: each detector amplifiers with a fifth-order time programming function can automatically change the attenuation of the output signal range and polarity.
    6. External Event Time Programming: four external events with twenty -order time programming, can be completed in three autosampler valves , control valves and automatic switching blowback valve ; may signal conversion between the two detectors .
    7. The user needs to be made specific gas chromatography for various purposes , multi-dimensional chromatography.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com