SCal Plus electronic soap film flowmeter Introduction: The SCal Plus electronic soap film flowmeter measures gas flow by combining its internal circuit control unit with sensitive components. The total measurement range is from 0.3mL/min to 30L/min, and the accuracy is better than ± 1% of the reading. It belongs to the first stage flowmeter. There are three types of flow measurement slots with different flow ranges to choose from. The flow measurement slot is replaceable and the control base can be shared. The electronic soap film flowmeter has a liquid crystal display with temperature, pressure, and volume calibration functions. Users can obtain the volumetric flow rate of the measured gas through on-site self calibration, and can measure the gas flow rate in a single measurement or take the average value after ten flow rate measurements. Gas flow calibration applicable to environmental monitoring instruments; Adopting infrared photoelectric sensing technology, it has strong anti-interference ability, accurate data, high calibration accuracy, and is easy to carry. It can be optionally equipped with a multi range gas flow calibration module, which can meet the flow calibration of most sampling instruments. It is widely used in metrological verification, environmental monitoring, labor protection and health, scientific research institutes, and other occasions that require gas flow calibration. Execution standard: JJG 586 2006 "Verification Regulations for Soap Film Flowmeters". Technical parameters: Measurement range: Low flow measurement tank: (0.3-600) mL/min Medium flow measurement tank: (20-6000) mL/min High flow measurement tank: (1-30) L/min Accuracy: ≤± 1% Measurement method: wet type Data display: Traffic (five digits) Operating environment: 0-50 ℃; 0-70% RH (no condensation) Size: Low flow measurement tank: 75mm × 80mm × 153mm Medium flow measurement slot: 87mm × 96mm × 184mm High flow measurement slot: 115mm × 125mm × 231mm
Introduction: The SCal Plus electronic soap film flowmeter measures gas flow by combining its internal circuit control unit with sensitive components. The total measurement range is from 0.3mL/min to 30L/min, and the accuracy is better than ± 1% of the reading. It belongs to the first stage flowmeter. There are three types of flow measurement slots with different flow ranges to choose from. The flow measurement slot is replaceable and the control base can be shared. The electronic soap film flowmeter has a liquid crystal display with temperature, pressure, and volume calibration functions. Users can obtain the volumetric flow rate of the measured gas through on-site self calibration, and can measure the gas flow rate in a single measurement or take the average value after ten flow rate measurements. Gas flow calibration applicable to environmental monitoring instruments; Adopting infrared photoelectric sensing technology, it has strong anti-interference ability, accurate data, high calibration accuracy, and is easy to carry. It can be optionally equipped with a multi range gas flow calibration module, which can meet the flow calibration of most sampling instruments. It is widely used in metrological verification, environmental monitoring, labor protection and health, scientific research institutes, and other occasions that require gas flow calibration. Execution standard: JJG 586 2006 "Verification Regulations for Soap Film Flowmeters".